000 05298nas a2200469 a 4500
005 20260818095011.0
008 201022s2020 th uu m rtt 0| a1eng d
035 _a.b12355185
099 9 _aAIT Thesis no.WM-20-21
100 0 _aWisut Termsintaveesuk
245 1 0 _aEffect of meteorological and building parameters on peak discharge for urban drainage design
260 _aPathum Thani, Thailand :
_bAsian Institute of Technology,
_c2020
300 _a1 online resource (112 leaves) :
_bill.
490 1 _aThesis;
_vno. WM-20-21
502 _aThesis (M. Eng.) - Asian Institute of Technology, 2020
500 _aA thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering in Water Engineering and Management
520 _aNowadays, an increase of urbanization negativity affects peak discharge for urban drainage design after sudden rain because land use and other human activities also influence the hydraulic characteristics of floods. Moreover, meteorological and building parameters also affect magnitude of rainfall sway by wind speed and vertical catchment area of building is not the same as that of horizontal. Both variables have not yet taken into urban drainage design. This study focuses on the hydraulic characteristics calculated from the interaction between wind-driven rainfalls and cascade of buildings using meteorological and building data. The numerical model is developed based on laminar flow condition. Nusselt equation is used in a modified kinematic wave model to compute the hydraulic characteristics of thin film along cascade of buildings. In highly developed areas, high-rise and tall buildings are constructed in a small catchment. As vertical area (Av) is greater than the drainage horizontal area (Ah), a ratio of Av and Ah affects peak discharge change. It seems that increasing vertical area influences peak discharge and it does not included in conventional design method which uses only the change of physical conditions for runoff coefficient (C). Furthermore, ratio of the WDR intensity through the imaginary vertical surface or wind-driven rainfall intensity (Rwdr) and the intensity of rainfall falling through a horizontal plane or horizontal rainfall intensity (Rh) also affect the peak discharge due to effect of wind speed and direction. The effects of meteorological and building data have been tested using numerical model. Conventional design of urban drainage has used empirical formula, rational method for surface discharge computation. It is subjective to determine appropriate C value. The result shows that the C value is linearly varied with peak discharge when rational method is modified to use in vertical plan, runoff coefficient increase 1.2 to 2.1 times due to effect of wind direction. Comparing peak discharge computed from present model and conventional method when building parameters are constant, it shows that percentage of absolute error errors between present model and rational method of peak discharge are similarly increased linearly when Rh increased, but the percentage of absolute errors are differently increased linearly when wind speed increased. Moreover, the percentage of absolute errors are differently decreased when wind direction increased. Time of concentration (tc) has been derived at the first time using result from the present model, and it shows relationship with height of building (H) and Rh. The higher Rh provides less tc on vertical plane. The present study successfully shows that interaction of meteorological and building parameters, estimated discharge both peak discharge and total discharge. The new design concept on urban drainage design using present numerical model should be promoted and revised in order to implement with development in highly urbanized area.
650 0 _aUrban runoff
650 0 _aDrainage
700 0 _aSutat Weesakul,
_eChairperson
700 1 _aBabel, Mukand Singh,
_eExamination Committee
700 0 _aSarawut Ninsawat
_eExamination Committee
700 0 _aSomchai Chonwattana,
_eExamination Committee
710 2 _aRoyal Thai Government Fellowship,
_eScholarship Donor
810 2 _aAsian Institute of Technology.
_tThesis;
_vno. WM-20-21
856 _3Full-Text
_uhttp://203.159.5.9/ait-thesis/detail.php?q=B08844
907 _a.b12355185
_bmnait
_cm
902 _a240425
998 _b0
_c201022
_dm
_ea
_fm
_g0
945 _lmnait
945 _lmnait
945 _lmnarc
945 _lmnarc
942 _c40
942 _c61
942 _c20
909 _aBarcode : 30050120888531
_bCREATED : 2020-10-20
_cRECORD # : i13304793
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
909 _aBarcode : -
_bCREATED : 2020-10-20
_cRECORD # : i1330480x
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
909 _aBarcode : 30050121011224
_bCREATED : 2021-03-15
_cRECORD # : i13332909
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 1
_iTOT CHKOUT : 0
_jTOT RENEW : 0
909 _aBarcode : 30050121011216
_bCREATED : 2021-03-15
_cRECORD # : i13332910
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 1
_iTOT CHKOUT : 0
_jTOT RENEW : 0
999 _c34482
_d34482