000 04863nam a2200433 4500
005 20260818095125.0
008 190598 th eng
035 _a.b10228962
099 9 _aAIT Thesis no. WA-83-7
100 1 _aLin, I-wan
245 1 0 _aEffect of upstream diversions and downstream diversions on overall operation of Choshui pumped storage hydropower system, Taiwan, R.O.C.
260 _aBangkok :
_bAsian Institute of Technology,
_c1982
300 _avii, 55, c. 31-37 p.
490 1 _aThesis ;
_vno. WA-83-7
500 _aA thesis submitted in partial fulfillment of the requirement for the degree of Master of Engineering, school of Engineering and Technology
502 _aThesis (M.Eng.) - Asian Institute of Technology,1982
520 _aA simulation model is developed to represent the overall Choshui hydro power system. The whole system consists of six reservoirs or ponds, namely, Wu Sheh, Wu Chieh, Sun Moon Lake, ·Ming Hu and Ming Tan lower reservoir, and Chi Chi reservoir, two pumped storage plants ·Ming Hu and Ming Tan and four conventional hydro plants Wu Sheh, Ta Kuan, Chu Kung, and Shui Li. (Figs.1 .1 , 1.2, and 1.3). The upstream diversion consisting of at most seven diversion dams, will divert the flow of each creek into a connecting tunnel and converge into the Sun Moon Lake. The Chi Chi dam is located at the downstream of the power system tailrace and headwork of the existing canal diversions, so its main functions are to regulate the uncontrolled flow and the release during the peak hour, and provide the additional regulated flow from the reservoir for irrigation purpose. The reservoirs and power plants are connected both in a series and in parallel. The system generates electricity and provides water for irrigation and downstream requirements. The hydrological data used cover 28 years from 1954 to 1981, while the recording of irrigation demand is 7 years from 1972 to 1978. One of the pumped storage projects, Ming Hu, is now under construction. Therefore, the case of excluding pumped storage project in operation will not exist in the system. Consequently, the most feasible combination of the Wu Sheh and Sun Moon Lake rule curves is recommended based upon the maximum power benefit and minimum downstream water shortage for irrigation. For estimating the power benefit, the peak and offpeak power rates are considered, at 2 . 09 NT$/kWh for peak power and at 1.25 NT$/kWh for offpeak power. The operating policy which yields the maximum power benefit and minimum downstream water shortage is selected. Two different release policies are considered: irrigation predominated a nd power generation predominated. Based on the objective of the simulation the case which yields highest maximum power benefit and minimum downstream water shortage should be selected. It is found that the highest maximum power benefit occur when taking power generation as higher priority. In this case the rule curve of Sun Moon Lake indicates that the Lake should be kept full at all time while for the Wu Sheh reservoir, the rule curve No. 13 for comparison purpose is selected. The case when irrigation is considered predominated is run. The maximum power benefit obtained is found to be lower than t he case when considering power generation as higher priority though less downstream water shortage can be achieved. In the study, t he MH and MT psp are operated under mixed pumped condition.
650 0 _aWater-power electric plants
_xTaiwan
700 1 _aTawatchai Tingsanchali,
_eChairperson
700 1 _aArbhabhirama Anat,
_eExamination Committee
700 1 _aNguyen Due Lien,
_eExamination Committee
710 2 _aTaiwan Power Company, R.O.C.,
_eScholarship Donor
810 2 _aAsian Institute of Technology.
_tThesis ;
_vno. WA-83-7
856 _3Full-Text
_uhttp://203.159.5.9/ait-thesis/detail.php?q=B21408
907 _a.b10228962
_bmnait
_cs
902 _a241008
998 _b2
_c951012
_dm
_ea
_fs
_g0
945 _lmnait
945 _lmnait
945 _lmnarc
945 _lmnarc
942 _c20
942 _c40
909 _aBarcode : 30050003069944
_bCREATED : 1994-05-17
_cRECORD # : i10278989
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
909 _aBarcode : 30050003069951
_bCREATED : 1994-05-17
_cRECORD # : i10278990
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
909 _aBarcode : 30050160036041
_bCREATED : 2016-05-02
_cRECORD # : i12877542
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
909 _aBarcode : 30050121028202
_bCREATED : 2022-10-18
_cRECORD # : i13408549
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
999 _c34769
_d34769