000 04886nas|a2200397 i 4500
005 20260818095219.0
008 030815s2004 th uzm rtt 00| a1eng d
035 _a.b11938985
099 9 _aAIT Thesis no.ST-04-05
100 0 _aChayut Cheejaroen
245 1 0 _aEffects of bond deterioration on seismic behavior of R/C interior beam-column joints without seismic detailing
260 _aPathum Thani, Thailand :
_bAsian Institute of Technology,
_c2004
300 _a229 leaves
490 1 _aThesis ;
_vno. ST-04-05
500 _aA thesis submitted in partial fulfillment of requirements for the degree of Master of Engineering, School of Engineering and Technology
502 _aThesis (M.Eng.) - Asian Institute of Technology, 2004
520 _aRecent studies have shown that Thailand is at higher seismic risk than one ever expected although Thailand located in a low to moderate seismicity seismic region and there has never been any severe earthquake damage in this country. There is a raise in the level of awareness about the possibility of seismic hazard. In addition, reinforced concrete structures in Thailand are usually designed without the consideration of seismic loading since building design code and construction practice in Thailand do not include modern seismic provisions. Therefore, the deficient detailing of the members can lead to questionable structural performance during seismic activity. Reinforced concrete beam-column frames are found to be typical in many low-rise to mid-rise buildings in Thailand and beam-column joint regions in such frame are of special interest because they are usually non-seismically detailed including no transverse reinforcement at joints, lap splice in column just above joint level, and construction joints just above and below the beam level. In this research, the quasi-static cyclic loading test was conducted on a beam-column subassemblage that is considered to be one of the most critical members against a seismic action. Structural indices, which indicate the seismic behavior of the beam-column subassemblages, were calculated based on the design documents of ten mid-rise RC mid-rise frame buildings. From the structural indices, interior beam-column subassemblages in Thailand normally are the strong column-weak beam type and can be separated into three groups based on tributary area of each subassemblage. Some might have a poor seismic performance but some might have a good seismic performance depend on the bond index and maximum joint shear stress over joint shear strength ratio. Three specimens representing typical RC mid-rise frame buildings were carefully designed based on the range of structural indices. The experimental results show that if bond condition along the beam bars passing through the interior joint is good enough, the so called joint shear failure shift to the ductile flexural failure in beam. However, almost specimen failed in joint shear failure mode because of the occurrence of bar slip. Bond deterioration along the beam longitudinal bars passing through the interior joint was considered to be the main cause of the degradation in strength and initial stiffness while high diagonal compressive force in joint caused the severity of diagonal crack in joint. If joint shear failure occurred, poor seismic performance could be observed through the experimental force-story drift relationship. For the specimens that failed in the joint region, the strength of specimen decreased more than 20% of peak resistance at 3.00% drift and further reduced approximately 45-60% of peak resistance at 5.00% drift. The peak resistance was found at 1.50%-1.75% drift while the peak strength of specimen that failed in the critical beam section was obtained at a story drift of 4.60% and then the strength dropped to approximately 60% of peak resistance at a story drift of 5.00%.
650 0 _aReinforced concrete
650 0 _aConcrete beams
700 0 _aPennung Warnitchai,
_eChairperson
700 0 _aPichai Nimityongskul,
_eExamination Committee
700 1 _aKim, Kidu,
_eExamination Committee
710 2 _aRoyal Thai Government,
_eScholarship donor
810 2 _aAsian Institute of Technology.
_tThesis ;
_vno. ST-04-05
856 _3Full-Text
_uhttp://203.159.5.9/ait-thesis/detail.php?q=B08984
907 _a.b11938985
_bmnait
_cu
902 _a240422
998 _b0
_c040903
_dm
_ea
_fu
_g0
945 _lmnait
945 _lmnarc
942 _c22
942 _c40
909 _aBarcode : 30050120818793
_bCREATED : 2014-04-30
_cRECORD # : i12795033
_dLPATRON : 1029032
_eLCHKIN : 2019-08-16
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 2
_iTOT CHKOUT : 2
_jTOT RENEW : 1
909 _aBarcode : 30050160068499
_bCREATED : 2016-08-04
_cRECORD # : i12933922
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
999 _c35032
_d35032