000 03850nam a2200385 4500
005 20260818095913.0
008 290998s1993 th r 0000|0 eng d
035 _a.b10244669
099 9 _aAIT Thesis no.ET-93-1
100 0 _aJirawat Nooritanon
245 1 0 _aEnergy targeting for an office building :
_ba case study of Thai Airways buildings
260 _aBangkok :
_bAsian Institute of Technology,
_c1993
300 _a94 leaves :
_bill.
490 1 _aThesis ;
_vno. ET-93-1
502 _aThesis (M.Eng.) - Asian Institute of Technology, 1993
500 _aA thesis submitted in partial fulfillment of the requirement for the degree of Master of Engineering.
520 _aThe commercial high-rise building in Bangkok have been constructed at rapid growth and their energy consumption are varied in the wide range due to the diversity in design construction, using purpose, operating period and etc. To consider the way for finding suitable amount of energy consumption of each building, energy targeting is needed. In this study, the energy targeting based on OTTV concept, proposed by S. Chirarattananon, is modify by considering the effects of (i) different type of areas, (ii) the use of OTTV calculation out-of normal office hours. To see the effects from (ii), one computer program specially used to calculated TDeq for any specific operating periods and types of wall materials is written. And the one existing building complex which is Thai Airways Building Complex is selected as a case study. This complex comprises with five buildings; Building No. I: the Office Building; Building No.2: Canteen; Building No.4: Mechanical building; Building No.6: Simulation Building and Building No.9: Crew building. The first three buildings are operated during normal office hours while the remaining buildings are operated from 7.00 to 24.00. After the analysis of past four years annual energy data and doing energy audit from the complex completed, the table for setting energy target is created and data from energy audit and recommended stand are filled. The final results show that by taking in account of different type of areas the accuracy of energy target can be improved around 40 percent but for using OTTV accounted for actual operating period, accuracy can be improved only 4 percent. Then summary can be written that within 95 percent of accuracy needs the ordinary OTTV method and standard value from table can be used for setting energy target. The final part is sensitivity analysis. The results show about the influences of change in each variable which will affect to the change in total energy consumption for each type of area in the complex. And the analysis can prove that errors from measurement have very small effect to the improvement on actual total energy consumption by changing the related parameters.
650 0 _aBuilding
_xThailand
_xBangkok
_xEnergy conservation
700 0 _aSurapong Chiraratananon,
_eChairperson
700 1 _aExell, R.H.B.,
_eExamination committee
700 0 _aSupachart C.,
_eExamination committee
710 2 _aCommission of the European Communities,
_eScholarship donor
810 2 _aAsian Institute of Technology.
_tThesis ;
_vno. ET-93-1
856 _3Full-Text
_uhttp://203.159.5.9/ait-thesis/detail.php?q=B16156
907 _a.b10244669
_bmnait
_cx
902 _a240401
998 _b2
_c951012
_dm
_ea
_fx
_g0
945 _lmnait
945 _lmnarc
942 _c22
942 _c40
909 _aBarcode : 30050120678833
_bCREATED : 2014-11-02
_cRECORD # : i1276212x
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
909 _aBarcode : 30050120367601
_bCREATED : 2016-08-06
_cRECORD # : i13024644
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
999 _c37698
_d37698