000 03669nas|a2200397 i 4500
005 20260817162059.0
008 271198s1987 th uzm rtt 00| a1eng d
035 _a.b10065581
099 9 _aAIT RSPR no. ET-87-24
100 0 _aSuchitra Ngamkajornvivat
245 1 0 _aAlcohol distillation :
_bfeasibility study of some energy conservation techniques
260 _aBangkok :
_bAsian Institute of Technology,
_c1987
300 _a157 p.
490 1 _aResearch studies project report ;
_vno. ET-87-24
500 _aA research study (9 credits) submitted in partial fulfillment of the requirement for the degree of Master of Engineering, School of Environment, Resources and Development
502 _aResearch Studies Project Report (M. Eng..) - Asian Institute of Technology, 1987
520 _aA study on energy used in TISTR alcohol pilot plant, a production capacity of 1500 litres anhydrous alcohol per day was conducted . The total energy consumption of the plant was 21202.87 MJ/day . It comprised of 97.5% fuel oil and 2 . 5% electricity , by quantity or 88 . 5% and 11.5% of the total energy bill for fuel oil and electricity respectively. Significant amount of energy , 99% of total energy , is distributed to the distillation process. The energy and availability analyses are used to identified locations, type and true magnitudes of waste energy, including losses and irreversibility from the system. These illustrated that the first law efficiency of boiler are 63 . 60% and 78.09% for the worst and best case respectively. And the major losses are losses due to dry flue gas and uncounted loss . The second law efficiency of boiler is 16.34% for the worst case and 20 . 06% for the best case. Energy conservation opportunities in the thermal energy systems are identified , analyzed and recommended. For the steam generation system , the installation of economizer is recommended to reduce the flue gas temperature . The possible saving is approximately 30468 Baht/year. In distillation, economic return of the potential conservation measures , by using heat pump , are analysed . Two heat pump systems are recommended. One is the reboiler flashing system, the possible saving is approximately 132987 Baht/year with nine month payback period. The other is external working fluid system. It provided a 75288 Baht/year of net saving and 2 . 2 year payback period . The application of membrane technology, pervaporation, was carried out to study the feasibility of replacing azeotropic distillation by pervaporation process to reduce significant amount of energy consumption in distillation process.
650 0 _aEnergy conservation
650 0 _aAlcohol as fuel
700 1 _aMora, Jean-Claude,
_eChairperson
700 0 _aPrida Wibulswas,
_eExamination Committee
700 1 _aBhattacharya, Sribas C.,
_eExamination Committee
710 2 _aEEC,
_eScholarship Donor
810 2 _aAsian Institute of Technology.
_tResearch studies project report ;
_vno. ET-87-24
856 _3Full-Text
_uhttp://203.159.5.9/ait-thesis/detail.php?q=B19010
907 _a.b10065581
_bmnait
_cy
902 _a240409
998 _b2
_c951012
_dm
_ea
_fy
_g0
945 _lmnait
945 _lmnarc
942 _c20
942 _c40
909 _aBarcode : 30050003123329
_bCREATED : 1995-10-13
_cRECORD # : i1006249x
_dLPATRON : 1011549
_eLCHKIN : 2006-07-28
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 1
_jTOT RENEW : 0
909 _aBarcode : 30050160015961
_bCREATED : 2016-03-31
_cRECORD # : i12917072
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
999 _c3789