000 03577nas a2200409 a 4500
005 20260818100053.0
008 071106s2007 th uu|m rtt 0| a1eng d
035 _a.b12013924
099 9 _aAIT Thesis no.EV-07-5
100 0 _aChanokkamon Cheawtada
245 1 0 _aEnhanced degradation of PCB by using ozone and TiO2
260 _aPathum Thani, Thailand :
_bAsian Institute of Technology,
_c2007
300 _a56 leaves :
_bill.
490 1 _aThesis ;
_vno. EV-07-5
500 _aA thesis proposal in partial fulfillment of the requirements for the degree of Master of Science in Environmental Engineering and Management Inter-University Program on Emvironmental Toxicology, Technology and Management, School of Environment, Resources and Development
502 _aThesis (M.Sc.) - Asian Institute of Technology - Chulabhorn Research Institute - Mahidol University, 2007
520 _aPCBs are synthetic compounds that have been widely used as transformer dielectric fluids, heat transfer fluids, and plasticizers. They are not easily degraded and can cause toxic effects to humans and animals. This study was carried out to investigate efficiency of PCB degradation by ozonation catalyzed by TiO2. A 300-ml lab scale reactor was filled with a synthetic wastewater containing PCB concentration at 1 and 5 mg/L, ozone concentrations were varied at 10 and 25 mg/L, Ti02 concentrations were varied at 3, 5, and 9 mg/L, and pH of the synthetic wastewater was varied at 3 and 9. The conditions that resulted in about 99% PCB removal were as follows: ozone dosage 900 mg-min/L; contact time 90 min; Ti02 9 mg/L; and pH 9. The first-order reaction rate constant of PCB removal under these conditions was found to be 0.0919 min-1. The efficiency of PCB degradation was found to increase with increasing TiO2, pH and contact time. Since Ti02 is a catalyst which produces synergistic effects with ozone on PCB degradation and high pH produces more OH radicals which activate the oxidation reactions, the higher these values were maintain in the reactor the more PCB degradation. The operation cost of ozone catalyzed by Ti02 for PCB degradation under the above condition was found to be US$ 1.21 /mg of PCB, which was lower than some conventional techniques employed for PCB degradation. The PCB reaction rate constant as found in the study could be applied determine the ozone reactor size, contact time, and the amount of ozone and TiO2 needed for PCB degradation
650 0 _aPolychlorinated biphenyls
700 0 _aChongrak Polprasert,
_eChairperson
700 0 _aPreeda Pakpian,
_eExamination Committee
700 0 _aApinya Thientanawat,
_eExamination committee
710 2 _aChulabhom Research Institute,
_eScholarship donor
710 2 _aMahidol University,
_eScholarship donor
710 2 _aAsian Institute of Technology,
_eScholarship donor
810 2 _aAsian Institute of Technology.
_tThesis ;
_vno. EV-07-5
856 _3Full-Text
_uhttp://203.159.5.9/ait-thesis/detail.php?q=B10805
907 _a.b12013924
_bmnait
_cu
902 _a240401
998 _b0
_c071106
_dm
_ea
_fu
_g0
945 _lmnait
945 _lmnarc
942 _c22
942 _c40
909 _aBarcode : 30050120743645
_bCREATED : 2014-02-13
_cRECORD # : i12764838
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
909 _aBarcode : 30050160049879
_bCREATED : 2016-05-30
_cRECORD # : i13003318
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
999 _c38383
_d38383