245 1 0 _aEvaluation of arsenic field test kits in Cambodia :
_bthrough confirmatory testing
260 _aPathum Thani, Thailand :
_bAsian Institute of Technology,
_c2003
300 _a78 leaves
490 1 _aThesis ;
_vno. EV-03-30
502 _aThesis (M.Sc.) - Asian Institute of Technology, 2003
500 _aA thesis submitted in partial fulfillment of the requirements for the degree of Master of Science.
520 _aFor a country like Cambodia with a significant groundwater arsenic problem, there is an urgent need for the arsenic-contaminated wells to be quickly identified and appropriate action to be taken. This will involve the testing of a large number of wells. A field testing kit made by Hach is currently used national-wide. The field Hach kit is based upon the Gutzeit method, which involves the reduction of arsenic to arsine gas, which reacts with mercuric bromide to form yellow colour. The determination of arsenic concentration is done by visual comparison of the coloured stain with a colour chart. The detection limit of the Hach kit is about 10 og/L. Since Hach kit is widely used it became necessary to evaluate its effectiveness and possible made suggestions for improvement. The Hach kit performance was evaluated in various ways including arsenic standard solution, samples preservation using hydrochloric and nitric acid, quality of the test strip, effect of hydrogen sulphide, colour scale reading and reaction time. Samples from 94 tube wells were tested by kit and by a reliable laboratory technique to ascertain the reliability. Overall the Hach kit performed well with arsenic standard solution as well as with preserved samples. Problems were noted in proper use and storage of test strips as well as interference from hydrogen sulphide. It was also noted that operators usually fail to record arsenic concentration in ranges between the two-gradation values of the colour scale. The 20-minutes reaction time recommended by the kit procedures was not adequate; 30 minutes was necessary to give good results. The comparison of the analytical results of 94 samples showed Hach kit usually gave higher result than either HG AAS or SDDC methods except at arsenic concentration below 10 og/L. The closest agreement between Hach kits and laboratory methods were observed when arsenic concentrations were low. There were 12 (13%) false positives found but no false negatives. All of the finding suggest further development is needed to improve methods of testing arsenic concentrations for less developed countries like Cambodia.
650 0 _aArsenic wastes
_zCambodia
700 1 _aVisvanathan, C.,
_eChairperson
700 1 _aNguyen, Thi Kim Oanh,
_eExamination Committee
700 0 _aPreeda Pakpian,
_eExamination Committee
710 2 _aSwedish International Development Agency (Sida),
_eScholarship Donor
810 2 _aAsian Institute of Technology.
_tThesis ;
_vno. EV-03-30
856 _3Full-Text
_u http://203.159.5.9/ait-thesis/detail.php?q=B08275
907 _a.b11929923
_bmnait
_cu
902 _a240417
998 _b0
_c040618
_dm
_ea
_fu
_g0
945 _lmnait
945 _lmnarc
942 _c22
942 _c40
909 _aBarcode : 30050120706535
_bCREATED : 2014-04-02
_cRECORD # : i12755783
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
909 _aBarcode : 30050160051107
_bCREATED : 2016-05-25
_cRECORD # : i12990590
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
999 _c40843
_d40843