| 245 | 1 | 0 | _aEvaluation of recharge and ground improvement using prefabricated vertical drains (PVD) for soft Bangkok clay |
| 260 |
_aBangkok : _bAsian Institute of Technology, _c2001 |
||
| 300 | _a148 leaves | ||
| 490 | 1 |
_aThesis ; _vno. GE-00-16 |
|
| 500 | _aA thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering, School of Engineering and Technology | ||
| 502 | _aThesis (M.Eng.) - Asian Institute of Technology, 2001 | ||
| 520 | _aLaboratory tests were conducted to investigate the effects of confinement at different pressures on discharge capacity of prefabricated vertical drain (PVD). Two types of PVDS were tested, namely: Mebra (MD7667A) and CN (Al). The test results indicated Mebra (MD7667 A) consistently yielded higher discharge capacity than CN (Al) because its filter jacket of Mebra (MD7667A) has higher tensile strength than CN (Al). Thus, the tensile strength of filter jacket significantly affected the discharge capacity of PVD. Moreover, the higher water contents of remolded clay confinement may also cause more deformation in the surrounding clay and may caused bending in the PVD. In the case, the PVD bending may have contributed fmther to the reduction of discharge capacity. For the settlements predicted of Reference Section at the Second Bangkok International Airport (SBIA), the settlements predicted by the PVD-SD software Version 2.3 and Asaoka's method were in good agreement with the observed data. However, the PVD-SD software was found to be quite useful are for the case of multi-layer soils having different physical prope1ties for each laye:r improvement with PVD. In addition, the back-calculated values of discharge capacity, %v, using the method of Asaoka agreed within the range of other investigators. Finally, the concept of removing piezometric level drawdown using PVDs was also observed in the filed test at the AIT campus. From the observed data, the PVD was effective in recharging the ground to remove the piezometric level drawdown up to the depth of PVD installation. | ||
| 650 | 0 | _aVertical drains | |
| 650 | 0 |
_aClay _zThailand _zBangkok _xTesting |
|
| 700 | 1 |
_aBergado, Dennes T., _eChairperson |
|
| 700 | 1 |
_aBalasubramaniam, A.S., _eExamination Committee |
|
| 700 | 1 |
_aMiura, Kinya, _eExamination Committee |
|
| 710 | 2 |
_aMahanakorn University of Technology, _eScholarship Donor |
|
| 810 | 2 |
_aAsian Institute of Technology. _tThesis ; _vno. GE-00-16 |
|
| 856 |
_3Full-Text _uhttp://203.159.5.9/ait-thesis/detail.php?q=B08174 |
||
| 907 |
_a.b11832083 _bmnait _cu |
||
| 902 | _a240407 | ||
| 998 |
_b0 _c010816 _dm _ea _fu _g0 |
||
| 945 | _lmnait | ||
| 945 | _lmnait | ||
| 945 | _lmnarc | ||
| 942 | _c20 | ||
| 942 | _c40 | ||
| 909 |
_aBarcode : 30050120716575 _bCREATED : 2000-03-19 _cRECORD # : i12253364 _dLPATRON : 1018000 _eLCHKIN : 2006-03-12 _f# RENEWALS : 0 _g# OVERDUE : 0 _hIUSE3 : 0 _iTOT CHKOUT : 8 _jTOT RENEW : 2 |
||
| 909 |
_aBarcode : 30050120382287 _bCREATED : 2000-03-19 _cRECORD # : i12253376 _dLPATRON : 1026557 _eLCHKIN : 2017-01-03 _f# RENEWALS : 0 _g# OVERDUE : 0 _hIUSE3 : 1 _iTOT CHKOUT : 7 _jTOT RENEW : 4 |
||
| 909 |
_aBarcode : 30050160054150 _bCREATED : 2016-05-23 _cRECORD # : i12984930 _dLPATRON : 0 _eLCHKIN : - _f# RENEWALS : 0 _g# OVERDUE : 0 _hIUSE3 : 0 _iTOT CHKOUT : 0 _jTOT RENEW : 0 |
||
| 999 |
_c41167 _d41167 |
||