000 02932nam a2200445 4500
005 20260818113250.0
008 th eng
035 _a.b11711413
099 9 _aAIT Thesis no. ISE-97-19
100 0 _aMaria Emerita Indraningrum
245 1 0 _aFacility layout improvement using a multiobjective decision model
260 _aBangkok :
_bAsian Institute of Technology,
_c1997
300 _a68 p.
490 1 _aThesis ;
_vno. ISE-97-19
500 _aA thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering, School of Advanced Technologies
502 _aThesis (M.Eng.) - Asian Institute of Technology, 1997
520 _aIncreased automation in manufacturing systems has produced a corresponding increase in networking complexity, particularly at the sensory/actuator level. To alleviate this problem, many users have turned to bus based network as a way of minimize the number of hard-wired point-to-point links. The aim of this special study is to discuss and evaluate different network protocols for manufacturing application, which are called fieldbus. The discuss on consists of description of fieldbus technology, mechanism, and classifications for manufacturing application. After the discussion about several protocols for communication in manufacturing application, we develop a methodology to connect automation devices like PLCs using the fieldbus standard called Profibus.
650 1 0 _aPlant layout
650 1 0 _aMultiple criteria decision making
700 1 _aPandey, P.C.,
_eChairperson
700 1 _aBohez, Erik L.J.,
_eExamination Committee
700 1 _aNaber, Helmut,
_eExamination committee
710 2 _aAtma Jaya Yogyakarta University, Yogyakarta, Indonesia,
_eScholarship donor
810 2 _aAsian Institute of Technology.
_tThesis ;
_vno. ISE-97-19
856 _3Full-Text
_uhttp://203.159.5.9/ait-thesis/detail.php?q=B14346
907 _a.b11711413
_bmnait
_cy
902 _a250422
998 _b0
_c980520
_dm
_ea
_fy
_g0
945 _lmnait
945 _lmnait
945 _lmnarc
945 _lmnarc
942 _c20
942 _c40
909 _aBarcode : 30050120816102
_bCREATED : 1998-05-20
_cRECORD # : i12068597
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
909 _aBarcode : 30050120816094
_bCREATED : 1998-05-20
_cRECORD # : i12068603
_dLPATRON : 1009531
_eLCHKIN : 2003-03-09
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 7
_jTOT RENEW : 1
909 _aBarcode : 30050160099056
_bCREATED : 2016-04-28
_cRECORD # : i12960214
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
909 _aBarcode : 30050121006257
_bCREATED : 2021-05-02
_cRECORD # : i13320956
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
999 _c42808
_d42808