245 1 0 _aFeasibility study for a separate air-conditioning system at AIT center
260 _aBangkok :
_bAsian Institute of Technology,
_c1985
300 _a97 p.
490 1 _aResearch studies project report ;
_vno. ET-85-5
500 _aA research study summitted in partial fulfilment of the requirements for the Degree of Master of Engineering, School of Environment, Resources and Development
502 _aResearch Studies Project Report (M. Eng.) - Asian Institute of Technology, 1985
520 _aAIT Center is the only building in the campus to which the existing central chiller plant has to supply the chilled water for maintaining physical comfort in the building during the night. The cooling load profile of the building resulted from cooling load estimation shows the oversize capacity of the existing 340-ton chiller unit especially during the night. The maximum of cooling load of the building is estimated to be about 230 tons (807 KW) occurring at bout 1500 hr in April. By considering the cooling load profile, the feasible period for an energy conservation measure appears to occur between 1900-0700 hrs. The thermodynamic analysis, by both first law and second law, consistently indicates that poor efficiencies of the existing chiller operation occur during the night. The average coefficient of performance, COP and the average exegetic efficiency of the whole system are just about 2.19 and 15.5% respectively. After the simulation of a proposed separate small chiller set of two 90-ton units, both thermodynamic and various economic analyses indicate the feasibility of the recommended system operating between 1900-0700 hr. the COP and the exegetic efficiency of the proposed system would be 3.55 and 24.7% respectively. the proposed system will save the electricity bill by about 645,000 Baht per years. for AIT and the investment cost can be recovered within 4 years. The refrigeration cost of the proposed system would be 1.13 Baht per KHh of refrigeration lower than that of the existing system. The net present worth, benefit cost ratio, and internal rate of return of the proposed system also show the positive results which are about 874,000 Baht, 1.29, and 20% respectively.
650 0 _aAir conditioning
700 0 _aPrida Wibulswas,
_eChairpeson
700 1 _aExell, Robert H.B.,
_eExamination Committee
700 1 _aReddy, T. A.,
_eExamination Committee
710 2 _aDAAD,
_eScholarship Donor
810 2 _aAsian Institute of Technology.
_tResearch studies project report ;
_vno. ET-85-5
856 _3Full-Text
_uhttp://203.159.5.9/ait-thesis/detail.php?q=B19831
907 _a.b1027392x
_bmnait
_cy
902 _a240401
998 _b2
_c951012
_dm
_ea
_fy
_g0
945 _lmnait
945 _lmnarc
942 _c22
942 _c40
909 _aBarcode : 30050120615157
_bCREATED : 2012-11-09
_cRECORD # : i12694630
_dLPATRON : 1029161
_eLCHKIN : 2019-11-19
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 1
_iTOT CHKOUT : 2
_jTOT RENEW : 5
909 _aBarcode : 30050160016456
_bCREATED : 2016-03-31
_cRECORD # : i12916584
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
999 _c43625
_d43625