| 245 | 1 | 2 | _aA feasibility study on ice storage in an office building in Bangkok |
| 260 |
_aBangkok : _bAsian Institute of Technology, _c1990 |
||
| 300 | _a159 p. | ||
| 490 | 1 |
_aThesis ; _vno. ET-90-1 |
|
| 500 | _aA thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering, School of Engineering and Technology | ||
| 502 | _aThesis (M.Eng.) - Asian Institute of Technology, 1990 | ||
| 520 | _aA feasibility study on ice storage in an office building in Bangkok, which has 24 floors in one block and 2 floors in another block, is described in this thesis. The ice storage under a partial and modified demand-limited design with constant proportion control are considered. It has been found from a preliminary results of an energy audit that the air conditioning system consumed about 61.1% of total building electrical energy consumption and chillers consumed about 51.8% of total electrical energy consumption in air-conditioning (A/C) system. The average coefficient of performance of the chillers is 4.77 at the daytime (450 ton chiller) and 3.45 at the nighttime (50 ton chiller) . The average system efficiency is 1.55 kW/ton. The DOE- 2. lC building energy analysis computer program was used to analyze the energy consumption in the studied building. Conventional heating ventilation air-conditioning (HVAC) system was compared to ice storage systems using simple payback periods, net present value and internal rate of return. It was found that at present electricity rate structure , partial storage is more economically feasible than other operating modes . But under a number of alternative time-of-day (TOD) rate structure, the modified demand-limited storage system present a better economic feasibility, especially when the energy charge for the off-peak period is differentiated from other period. | ||
| 650 | 0 | _aHeat storage | |
| 650 | 0 | _aCooling load | |
| 700 | 0 |
_aSurapong Chiraratananon, _eChairperson |
|
| 700 | 1 |
_aBhattacharya, Sribas C., _eExamination Committee |
|
| 700 | 1 |
_aMohanty, B., _eExamination Committee |
|
| 700 | 1 |
_aLapillonne, Bruno, _eExamination Committee |
|
| 710 | 2 |
_aThe Government of France, _eScholarship Donor |
|
| 810 | 2 |
_aAsian Institute of Technology. _tThesis ; _vno. ET-90-1 |
|
| 856 |
_3Full-Text _uhttp://203.159.5.9/ait-thesis/detail.php?q=B18305 |
||
| 907 |
_a.b10029151 _bmnait _cx |
||
| 902 | _a240409 | ||
| 998 |
_b2 _c951012 _dm _ea _fx _g2 |
||
| 945 | _lmnait | ||
| 945 | _lmnait | ||
| 945 | _lmnarc | ||
| 942 | _c20 | ||
| 942 | _c40 | ||
| 909 |
_aBarcode : 30050003105292 _bCREATED : 1995-10-13 _cRECORD # : i10012096 _dLPATRON : 0 _eLCHKIN : - _f# RENEWALS : 0 _g# OVERDUE : 0 _hIUSE3 : 0 _iTOT CHKOUT : 0 _jTOT RENEW : 0 |
||
| 909 |
_aBarcode : 30050003105284 _bCREATED : 1995-10-13 _cRECORD # : i10012102 _dLPATRON : 1015538 _eLCHKIN : 2003-02-08 _f# RENEWALS : 0 _g# OVERDUE : 0 _hIUSE3 : 0 _iTOT CHKOUT : 3 _jTOT RENEW : 0 |
||
| 909 |
_aBarcode : 30050120344782 _bCREATED : 2016-06-15 _cRECORD # : i13039738 _dLPATRON : 0 _eLCHKIN : - _f# RENEWALS : 0 _g# OVERDUE : 0 _hIUSE3 : 0 _iTOT CHKOUT : 0 _jTOT RENEW : 0 |
||
| 999 |
_c43699 _d43699 |
||