100 1 _aKim, Han Ki
245 1 0 _aFinite element analysis of soft ground improved by prefabicated vertical drains
260 _aBangkok :
_bAsian Institute of Technology,
_c1999
300 _a105 leaves
490 1 _aThesis ;
_vno. GE-98-22
500 _aA thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering, School of Engineering and Technology
502 _aThesis (M.Eng.) - Asian Institute of Technology, 1999
520 _aThis study performed a detailed investigation on FEM analysis of unit cells and full scale PVD (Prefabricated Vertical Drain) improved ground with embankment surcharge loading. Interface element was introduced to simulate ve1tical drain with finite permeability to take well resistance into consideration. Based on equivalent discharge rate under confined flow condition, an equivalent horizontal permeability was determined to consider smear effect. Fmthermore, FEM analysis incorporated with the proposed matching schemes were performed on axisymmetric unit cell. The numerical results were compared with the theoretical solutions from Zeng (1988). Excellent agreements are found in comparisons. Consequently, the effectiveness of the proposed matching schemes is identified. A series of parametric studies based on the proposed matching scheme, were performed for two layered unit cell and the evaluation of well resistance. The numerical results of two layered unit cell were compared with the theoretical solutions from Onoue (1988). Excellent agreements further identify the applicability of the proposed matching schemes to the multi-layered ground improved by PVD. However, according to the numerical results, the well resistance factor proposed by Hansbo (1979) overestimates the well resistance of vertical drain with shorter installation length. In addition, the proposed matching schemes were employed to convert actual radial flow to two-dimensional plane strain flow based on the equivalent average degree of consolidation and discharge capacity of vertical drain. Well resistance is automatically considered by interface elements, which possesses equivalent discharge capacity to vertical drain in axisymmetric case. Meanwhile, the smear effect proposed by Hird et. al (1992) was also included in the analysis. Eventually, the proposed matching schemes were applied to full scale PVD improved ground with embankment surcharge loading. The evaluation of well resistance was carried out in term of consolidation rate. The numerical results show that significant well resistance existed during consolidation process in the full scale test embankment.
650 0 _aFinite element method
650 0 _aSoil consolidation
700 1 _aDer Guey, Lin,
_eChairperson
700 1 _aBergado, Dennes T.,
_eExamination Committee
700 0 _aNoppadol Phien-Wej,
_eExamination Committee
810 2 _aAsian Institute of Thesis ;
_vno. GE-98-22
856 _3Full-Text
_uhttp://203.159.5.9/ait-thesis/detail.php?q=B12520
907 _a.b11765008
_bmnait
_cy
902 _a240420
998 _b0
_c991119
_dm
_ea
_fy
_g0
945 _lmnait
945 _lmnait
945 _lmnarc
942 _c20
942 _c40
909 _aBarcode : 30050120717128
_bCREATED : 1998-06-22
_cRECORD # : i1216382x
_dLPATRON : 1012150
_eLCHKIN : 2002-11-04
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 4
_iTOT CHKOUT : 5
_jTOT RENEW : 1
909 _aBarcode : 30050120717102
_bCREATED : 1998-06-22
_cRECORD # : i12163831
_dLPATRON : 1010999
_eLCHKIN : 2006-05-11
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 5
_iTOT CHKOUT : 11
_jTOT RENEW : 15
909 _aBarcode : 30050160080809
_bCREATED : 2016-05-17
_cRECORD # : i1297996x
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
999 _c44858
_d44858