245 1 0 _aFrequency stability analysis of virtual power plants in a microgrid using load droop control method
260 _aPathum Thani, Thailand :
_bAsian Institute of Technology,
_c2018
300 _a76 leaves :
_bill. +
_e1 online resource
490 1 _aThesis ;
_vno. ET-18-12
500 _aA thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering in Energy
502 _aThesis (M.Eng.) - Asian Institute of Technology, 2018
520 _aWind and solar energy sources are cost-effective to sustenance the generation part of energy in the future energy demand. Moreover, renewable energy sources (RESs) will substitute for the traditional generation. RESs have the inherent fluctuation and intermittence of power output of these sources. The type of WTs is considered the doubly-fed induction generator (DFIG). Therefore, this uncertainty of these generators may exacerbate the stability and protection of power system. Energy storage systems and dump loads were significant to disentangle this problem. However, they are very expensive for this fluctuation. Therefore, the coordination control between RESs and controllable load in virtual power plant (VPP) is proposed in this study. The control method of power consumption in controllable load is also proposed for providing the power output of the VPP. Moreover, the coordination between the power output of RESs and the droop load power consumption of controllable loads can provide the flexibly power output of the VPP. Furthermore, the frequency droop control of controllable loads will response the frequency deviation. When the system frequency is over frequency in power system, the controllable loads will increase their power consumption in the VPP for the frequency regulation. Moreover, the frequency droop control of the power consumption of these loads will decrease their power consumption when the system frequency dropped. WTs have the over power reduction to control the power output of WTs when grid frequency increased. Therefore, VPP is externally adjustable and fulfill important functions electrically connected with the use of energy resources, such as distributed control frequency. The island microgrid and IEEE 33 bus system are the test system of this work. This simulation study the load variation in this system. VPP will included the WTs and PVs for the island microgrid. Moreover, IEEE 33 bus system is included the DFIG and diesel generators. For this system, This work use the DIgSILENT software for studying the system frequency variation by the coordination between the control of WTs and the frequency droop control of the controllable loads in the virtual powerplant. Simulation results provide 3 cases of island microgrid: 2 WTs are installed in the VPP, PV and WT included in the VPP and PVs installed in VPP. Moreover, the controllable load provide the two group of loads to response the frequency deviation. Simulation results confirm the effectiveness of the VPP in providing support to the microgrid frequency of the island microgrid and IEEE 33 bus system.
650 0 _aElectric power-plants
_xDecision making
650 0 _aMicrogrids (Smart power grids)
650 0 _aRenewable energy sources
_xAnalysis
700 1 _aSingh, Jai Govind,
_eChairperson
700 0 _aWeerakorn Ongsakul,
_eExamination Committee
700 1 _aKuwornu, John K. M.,
_eExamination committee
710 2 _aRoyal Thai Government Fellowship,
_eScholarship donor
810 2 _aAsian Institute of Technology.
_tThesis ;
_vno. ET-18-12
856 _3Full-Text
_uhttp://203.159.5.9/ait-thesis/detail.php?q=B02378
907 _a.b12307233
_bmnait
_cm
902 _a240422
998 _b0
_c210209
_dm
_ea
_fm
_g0
945 _lmnait
945 _lmnait
945 _lmnarc
945 _lmnarc
942 _c40
942 _c61
942 _c20
909 _aBarcode : 30050120897086
_bCREATED : 2019-04-25
_cRECORD # : i13179688
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
909 _aBarcode : -
_bCREATED : 2019-04-25
_cRECORD # : i1317969x
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
909 _aBarcode : 30050121013832
_bCREATED : 2021-09-02
_cRECORD # : i13323088
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
909 _aBarcode : 30050121013824
_bCREATED : 2021-09-02
_cRECORD # : i1332309x
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
999 _c47374
_d47374