000 04946nas|a2200397 a 4500
005 20260817162537.0
008 070824s2006 th uu|m rtt 0| a1eng d
035 _a.b12020424
099 9 _aAIT Thesis no.ET-06-19
100 1 _aAngammana, Mohottige Chitral Jayasanka
245 1 0 _aAnalytical study of factors affecting to electromechanical oscillations in power systems
260 _aPathum Thani, Thailand :
_bAsian Institute of Technology,
_c2006
300 _a130 p. :
_bill.
490 1 _aThesis ;
_vno. ET-06-19
500 _aA thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering, School of Environment, Resources and Development
502 _aThesis (M.Eng.) - Asian Institute of Technology, 2006
520 _aThe origin of inter-area oscillations can be illustrated by a spring-mass system, which is a mechanical analogue of a two area power system. The masses represent the aggregated inertias of the rotating generators and turbines of both areas, each having a well meshed grid inside the areas. The spring corresponds to a relatively weak interconnection line. Electromechanical oscillations are inherent to interconnected power systems. However, the frequency of oscillations and the number of generators that oscillate in any electromechanical oscillatory node depend on the structure of the power system network. Low frequency electromechanical oscillations occur when existing generation and load areas are connected to other similar areas by relatively weak transmission lines. Weak interconnections are obvious in many interconnected systems, for example, when two independent electric grids arc interconnected for the first time through one or two tie lines. However, in systems that have been interconnected for some time, such as the WSCC interconnected system, and that are being stressed by increased load, weak links are less obvious. Often, the first signs of trouble are low frequency oscillations becoming unstable. The connection between loading and stability is not always understandable. It is also unclear which contingencies may lead to oscillatory instability. Electromechanical oscillations in power systems are essentially linear in character. That is, the frequency and damping of an oscillation may be calculated from a dynamic system model linearized for small changes about a particular operating condition. The eigenvalues of the linear model give the frequency and damping of the system oscillations. The eigenvectors indicate the relative magnitude and phase angle between the state variables (in classical generator models, there are two states per generator, the changes in rotor angle and speed). In systems having a number of low frequency inter-area modes, we can use the coherency of the angle components of eigenvectors of the inter-area modes to identify relatively closely coupled generators. More than this, we can also identify those buses that have voltage phase angles that are coherent with the angles of a set of coherent generators. This divides the system into sets of coherent buses and generators equal in number to the number of inter-area modes. The tie lines between one coherent group and another are the weak connections that are the root cause of the inter-area oscillations. Here we list documented cases of oscillatory instability and review to illustrate the characteristics of the problems faced if oscillatory stability is not well managed. The cases arc described briefly in chapter 3. This Thesis examines in detail the relationship between low frequency oscillations and network parameters such as line reactance as well as loading. The basis of the analytical study will be on single machine infinite bus system. The results will be proved by eigenvalue analysis and time domain simulation. Further clarification has been done using two area test system
650 0 _aOscillations
650 0 _aElectric power systems
700 1 _aNadarajah, Mithulananthan,
_eChairperson
700 0 _aSurapong Chiraratananon,
_eExamination Committee
700 0 _aWeerakorn Ongsakul,
_eExamination Committee
710 2 _aAsian Development Bank - Japan Scholarship Program (ADB - JSP),
_eScholarship donor
810 2 _aAsian Institute of Technology.
_tThesis ;
_vno. ET-06-19
856 _3Full-Text
_uhttp://203.159.5.9/ait-thesis/detail.php?q=B10585
907 _a.b12020424
_bmnait
_cu
902 _a240401
998 _b0
_c070824
_dm
_ea
_fu
_g0
945 _lmnait
945 _lmnarc
942 _c22
942 _c40
909 _aBarcode : 30050120602080
_bCREATED : 2014-11-02
_cRECORD # : i12761709
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 1
_iTOT CHKOUT : 0
_jTOT RENEW : 0
909 _aBarcode : 30050120369391
_bCREATED : 2016-07-06
_cRECORD # : i13021059
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
999 _c5372
_d5372