| 100 | 0 | _aRam Wattanawerawong | |
| 245 | 1 | 0 | _aHealth monitoring of a three-span contineous prestressed concrete bridge in Bangkok |
| 260 |
_aBangkok : _bAsian Institute of Technology, _c2003 |
||
| 300 | _a68 leaves | ||
| 490 | 1 |
_aThesis ; _vno. ST-03-23 |
|
| 500 | _aA thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering, School of Engineering and Technology | ||
| 502 | _aThesis (M.Eng.) - Asian Institute of Technology, 2003 | ||
| 520 | _aThe development and implementation of the bridge health monitoring system of the Taksin Bridge, which has already been carried out by Infrastructure Monitoring and Management System (IMMS) Company, are presented and discussed in this research. The Taksin Bridge, over 20 years old, is twin bridges and consists of three-span continuous pre-stressed concrete single box-girders. Currently, the monitor installed at the bridge has 24 channels of different sensor types collecting data such as strains, accelerations, temperature, and movement of support. The monitoring signals are obtained continuously and provide very valuable but limited information. It would seem that the main challenge is to interpret the meaning of the measurements and observations intelligently and systematically. In this research, therefore, we try to interpret the meaning of the health monitoring signals by using a reliable and accurate FE model which is validated by comparing the predicted natural frequencies and mode shapes with the ambient vibration test by Petchroen (2002). A comparison of the experimental results with those by the FE model method indicated a higher degree of correlation. The development and calibration of the FE model are illustrated. Up to now, we have carried out the studies on an investigation of the behavior of this bridge under thermal loadings by using calibrated FE model. It is found that a sinecurve pattern of a mean value of a statistical data is significantly caused by the effects of the temperature change. | ||
| 650 | 0 |
_aBridges _zThailand _zBangkok |
|
| 650 | 0 | _aFinite element method | |
| 700 | 0 |
_aPennung Warnitchai, _eChairperson |
|
| 700 | 0 |
_aPichai Nimityongskul, _eExamination Committee |
|
| 700 | 1 |
_aKim, Kidu, _eExamination Committee |
|
| 710 | 2 |
_aRTG Fellowships, _eScholarship donor |
|
| 810 | 2 |
_aAsian Institute of Technology. _tThesis ; _vno. ST-03-23 |
|
| 856 |
_3Full-Text _uhttp://203.159.5.9/ait-thesis/detail.php?q=B08916 |
||
| 907 |
_a.b11894088 _bmnait _cu |
||
| 902 | _a240404 | ||
| 998 |
_b0 _c030815 _dm _ea _fu _g0 |
||
| 945 | _lmnait | ||
| 945 | _lmnarc | ||
| 942 | _c22 | ||
| 942 | _c40 | ||
| 909 |
_aBarcode : 30050120745558 _bCREATED : 2014-04-29 _cRECORD # : i12792743 _dLPATRON : 1029077 _eLCHKIN : 2019-08-13 _f# RENEWALS : 0 _g# OVERDUE : 0 _hIUSE3 : 1 _iTOT CHKOUT : 1 _jTOT RENEW : 0 |
||
| 909 |
_aBarcode : 30050160067699 _bCREATED : 2016-04-19 _cRECORD # : i12937587 _dLPATRON : 0 _eLCHKIN : - _f# RENEWALS : 0 _g# OVERDUE : 0 _hIUSE3 : 0 _iTOT CHKOUT : 0 _jTOT RENEW : 0 |
||
| 999 |
_c54509 _d54509 |
||