000 04214nam a2200445 4500
005 20260818133423.0
008 300998s1995 th r 0000|0 eng d
035 _a.b11510808
099 9 _aAIT Thesis no. ET-95-04
100 0 _aKosit Siwanansakul
245 1 0 _aHeat transfer through radiant barrier :
_ban experimental study
260 _aBangkok :
_bAsian Institute of Technology,
_c1995
300 _a105 leaves +
_e1 online resource
490 1 _aThesis ;
_vno. ET-95-4
500 _aA thesis submitted in partial fulfillment of the requirement for the degree of Master of Engineering
502 _aThesis (M.Eng.) - Asian Institute of Technology, 1995
520 _aKnowledge and understanding of heat transfer through a roof to an air-conditioned building have become a necessity in the importance aspect of providing comfort to human being as well as for the ration use of energy that means benefiting both individual building owners and the national economy. The mechanism of heat transfer is a dynamic phenomenon influenced by many factors such as instantaneous solar radiation intensity, the thermal properties of materials, interior and ambient temperature. For the most part of the world heat transfer coefficient recommended by ASHRAE is adequate to use. But this figure will have more accuracy if the experimental study is set up for the case of a country with low wind speed. Two types of the roof, the tilted and flat roof made from CPAC Monia tiles and cellocrate sheet respectively, are used to test with the variations of radiant barrier TYVEK, glass wool and gypsum board in the case of over purlin, under roof truss or as flat ceiling configurations under no ventilation or ventilation condition in the working hours. Heat flux and temperature results are given in graphical and tubular forms. The configuration of radiant barrier as flat ceiling is the best configuration among over purlin or under roof truss not only no ventilation but also ventilation. Radiant barrier as flat ceiling under ventilation is the best among other types of testing insulation material either under ventilation or no ventilation for the tilted roof. Radiant barrier as flat ceiling under no ventilation is the best among other types of testing insulation material under no ventilation for the flat roof. The simulation model using the finite different method program shows qualitative well prediction for heat flux through roof compared with using the heat flux meter while temperature prediction using model is fair compared with using thermocouples and the heat flux meter. This may come from time lagging of measurement using the heat flux meter and the accuracy of the data logger and the multiplexer due to rainfall coming to the experiment room.
650 1 0 _aHeat
_xTransmission
700 0 _aSurapong Chiraratananon,
_eChairperson
700 1 _aKarmazsin, Etienne,
_eExamination committee
700 1 _aMalik, Arif Saeed,
_eExamination committee
700 1 _aGiap, Van Dang,
_eExamination committee
710 2 _aRoyal Thai Government,
_eScholarship donor
810 2 _aAsian Institute of Technology.
_tThesis ;
_vno. ET-95-4
856 _3Full-Text
_uhttp://203.159.5.9/ait-thesis/detail.php?q=B15185
907 _a.b11510808
_bmnait
_cv
902 _a240404
998 _b0
_c960731
_dm
_ea
_fv
_g0
945 _lmnait
945 _lmnait
945 _lmnarc
945 _lmnarc
942 _c20
942 _c40
909 _aBarcode : 30050120677900
_bCREATED : 1995-03-03
_cRECORD # : i11811572
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
909 _aBarcode : 30050120677918
_bCREATED : 1995-03-03
_cRECORD # : i11811584
_dLPATRON : 1009811
_eLCHKIN : 1998-03-13
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 5
_jTOT RENEW : 2
909 _aBarcode : 30050120366942
_bCREATED : 2016-06-13
_cRECORD # : i13033827
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
909 _aBarcode : 30050120366959
_bCREATED : 2016-06-13
_cRECORD # : i13033839
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
999 _c54705
_d54705