000 03777nam a2200421 4500
005 20260818134012.0
008 120598 th eng
035 _a.b10341705
099 9 _aAIT Thesis no. WA-79-10
100 0 _aChainarong Na Lampoon
245 1 0 _aHydraulic design of tank irrigation schemes
260 _aBangkok :
_bAsian Institute of Technology,
_c1980
300 _aix, 165 p.
490 1 _aThesis ;
_vno. WA-79-10
500 _aA thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering, School of Engineering and Technology
502 _aThesis (M.Eng.) - Asian Institute of Technology, 1980
520 _aA multiple regression analysis is used to find the relationship between water shed area, A, average catchment rainfall, R, and annual streamflow, Q, of the small watershed area not greater than 1500 sq. km. The peak discharge estimated by TOMINAGA (1979) for the small irrigation project in Northeast is adopted to compute the peak discharge used for spillway design when the size of watershed area is known, the peak discharge per unit watershed area can be estimated from the graphs provided :(for 10, 20, 30 year s recurrence interval). Inlet drop spillway and Ogee spillways have been designed pass the peak discharge. Inlet drop spillway of 6-pipe row having a maximum diameter of 1.00 m can pass the peak discharge up to 39.5 ems when the dam height is 10.00 m. Ogee spill way having vertical and slope upstream face are selected in design. The crest length of spillways is upto 60.0 m. and the head of water over the crest ranges between 0.20 m and 1 .80 m, the peak discharge is upto 250 ems. Common outlet pipes have been designed to deliver water from reservoir to irrigation canals or the river. The size of pipe diameters are 0 . 20, 0 .30, 0.40, 0.50, 0.60 and 0.80 m. In some case this out let may be design in conjunction with a spillway for economy . Earth dams having the height upto 10.00 m have been designed. An earth canal with side slope of 1 vertical: 1 . 5 horizontal in section has been designed for distribution systems. Check, check drop and drop structures have been designed for on-farm system structures. 0 The 90 V-notch and the Cut-Throat Flume are devices used to measure the discharge in irrigation canals. The tables and graphed are investigated and provided for design purposes. These can be used t o expedite the design of all above structures.
650 0 _aHydraulic structures
_xThailand, Northeastern
_xDesign and construction
700 1 _aEggers, Helmut,
_eChairperson
700 1 _aOverbeek, Henk Jen,
_eExamination Committee
700 0 _aApichart Anukularmphai,
_eExamination Committee
700 0 _aNibondh Saiham,
_eExamination Committee
710 2 _aCarl Duisberg Gesellschaft,
_eScholarship Donor
810 2 _aAsian Institute of Technology.
_tThesis ;
_vno. WA-79-10
856 _3Full-Text
_uhttp://203.159.5.9/ait-thesis/detail.php?q=B22154
907 _a.b10341705
_bmnait
_cs
902 _a250523
998 _b2
_c951012
_dm
_ea
_fs
_g0
945 _lmnait
945 _lmnait
945 _lmnarc
942 _c20
942 _c40
909 _aBarcode : 30050003068391
_bCREATED : 1994-05-17
_cRECORD # : i10424519
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
909 _aBarcode : 30050003068383
_bCREATED : 1994-05-17
_cRECORD # : i10424520
_dLPATRON : 1028592
_eLCHKIN : 2018-06-02
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 1
_iTOT CHKOUT : 1
_jTOT RENEW : 0
909 _aBarcode : 30050160040233
_bCREATED : 2016-01-15
_cRECORD # : i12868085
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
999 _c56772
_d56772