| 000 | 03777nam a2200421 4500 | ||
|---|---|---|---|
| 005 | 20260818134012.0 | ||
| 008 | 120598 th eng | ||
| 035 | _a.b10341705 | ||
| 099 | 9 | _aAIT Thesis no. WA-79-10 | |
| 100 | 0 | _aChainarong Na Lampoon | |
| 245 | 1 | 0 | _aHydraulic design of tank irrigation schemes |
| 260 |
_aBangkok : _bAsian Institute of Technology, _c1980 |
||
| 300 | _aix, 165 p. | ||
| 490 | 1 |
_aThesis ; _vno. WA-79-10 |
|
| 500 | _aA thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering, School of Engineering and Technology | ||
| 502 | _aThesis (M.Eng.) - Asian Institute of Technology, 1980 | ||
| 520 | _aA multiple regression analysis is used to find the relationship between water shed area, A, average catchment rainfall, R, and annual streamflow, Q, of the small watershed area not greater than 1500 sq. km. The peak discharge estimated by TOMINAGA (1979) for the small irrigation project in Northeast is adopted to compute the peak discharge used for spillway design when the size of watershed area is known, the peak discharge per unit watershed area can be estimated from the graphs provided :(for 10, 20, 30 year s recurrence interval). Inlet drop spillway and Ogee spillways have been designed pass the peak discharge. Inlet drop spillway of 6-pipe row having a maximum diameter of 1.00 m can pass the peak discharge up to 39.5 ems when the dam height is 10.00 m. Ogee spill way having vertical and slope upstream face are selected in design. The crest length of spillways is upto 60.0 m. and the head of water over the crest ranges between 0.20 m and 1 .80 m, the peak discharge is upto 250 ems. Common outlet pipes have been designed to deliver water from reservoir to irrigation canals or the river. The size of pipe diameters are 0 . 20, 0 .30, 0.40, 0.50, 0.60 and 0.80 m. In some case this out let may be design in conjunction with a spillway for economy . Earth dams having the height upto 10.00 m have been designed. An earth canal with side slope of 1 vertical: 1 . 5 horizontal in section has been designed for distribution systems. Check, check drop and drop structures have been designed for on-farm system structures. 0 The 90 V-notch and the Cut-Throat Flume are devices used to measure the discharge in irrigation canals. The tables and graphed are investigated and provided for design purposes. These can be used t o expedite the design of all above structures. | ||
| 650 | 0 |
_aHydraulic structures _xThailand, Northeastern _xDesign and construction |
|
| 700 | 1 |
_aEggers, Helmut, _eChairperson |
|
| 700 | 1 |
_aOverbeek, Henk Jen, _eExamination Committee |
|
| 700 | 0 |
_aApichart Anukularmphai, _eExamination Committee |
|
| 700 | 0 |
_aNibondh Saiham, _eExamination Committee |
|
| 710 | 2 |
_aCarl Duisberg Gesellschaft, _eScholarship Donor |
|
| 810 | 2 |
_aAsian Institute of Technology. _tThesis ; _vno. WA-79-10 |
|
| 856 |
_3Full-Text _uhttp://203.159.5.9/ait-thesis/detail.php?q=B22154 |
||
| 907 |
_a.b10341705 _bmnait _cs |
||
| 902 | _a250523 | ||
| 998 |
_b2 _c951012 _dm _ea _fs _g0 |
||
| 945 | _lmnait | ||
| 945 | _lmnait | ||
| 945 | _lmnarc | ||
| 942 | _c20 | ||
| 942 | _c40 | ||
| 909 |
_aBarcode : 30050003068391 _bCREATED : 1994-05-17 _cRECORD # : i10424519 _dLPATRON : 0 _eLCHKIN : - _f# RENEWALS : 0 _g# OVERDUE : 0 _hIUSE3 : 0 _iTOT CHKOUT : 0 _jTOT RENEW : 0 |
||
| 909 |
_aBarcode : 30050003068383 _bCREATED : 1994-05-17 _cRECORD # : i10424520 _dLPATRON : 1028592 _eLCHKIN : 2018-06-02 _f# RENEWALS : 0 _g# OVERDUE : 0 _hIUSE3 : 1 _iTOT CHKOUT : 1 _jTOT RENEW : 0 |
||
| 909 |
_aBarcode : 30050160040233 _bCREATED : 2016-01-15 _cRECORD # : i12868085 _dLPATRON : 0 _eLCHKIN : - _f# RENEWALS : 0 _g# OVERDUE : 0 _hIUSE3 : 0 _iTOT CHKOUT : 0 _jTOT RENEW : 0 |
||
| 999 |
_c56772 _d56772 |
||