000 04096nas|a2200433 i 4500
005 20260818143539.0
008 160399s1991 th uzm rtt 00| a1eng d
035 _a.b10366325
099 9 _aAIT Thesis no.EV-91-5
100 1 _aHsu, Ta-lin
245 1 0 _aIntegrated system for urban sewage treatment (biodisc, activated sludge and water hyacinth)
260 _aBangkok :
_bAsian Institute of Technology,
_c1991
300 _a90 p.
490 1 _aThesis ;
_vno. EV-91-5
500 _aA thesis study submitted in partial fulfillment of the requirements for the degree of Master of Engineering, School of Environment, Resources and Development
502 _aThesis (M.Eng.) - Asian Institute of Technology, 1991
520 _aThe present paper reported herein was conducted to study the sources and characteristics of an important urban sewage source, an office wastewater and to evaluate a treatment process consisting of integrated system of BIODISC,ACTIVATED SLUDGE AND WATER HYACINTH. Major wastewater sources were domestic wastewater from office building. The pattern of the wastewater flows was found to be high variable on hourly basis and wastewater quality was classified as to be high nutrient BOD:N:P = 84:23:1. The combined wastewater had an average BOD value of 225 mg/l, COD of 418 mg/l, SS of 151 mg/l. The treatment process of combined Biodisc, Activated Sludge and water hyacinths has been studied in full scale plant. This system consisted of completely mixed biological treatment tank. In which suspended solids were kept in suspension by the rotating drum. The aeration drum was a wheel with pipe with plastic plate inside served as support material for attached growth. The supply of oxygen for the microorganism film and suspended microorganism by rotating the pipe-wheel. In this treatment process, 71 and 90 percent of SCOD and SBOD could be removed, respectively. partial nitrification also be found in bio-tank. It has been demonstrated that the first order specific SBOD removal rate (k) is about 0.037 l/mg VSS.day. In this study, there are some weakness of designing in this treatment plant to be found. (1) aeration disturb settling. ( 2 ) short circuit of raw sewage into settling. (3) shock hydraulic load due to oversize dosing pump and no suitable equalization. In summary, this treatment process is acceptable. The k value are normal in compare to with other activated sludge process. The concentration of oxygen in mixed liquor presented more than adequate. On the maintenance and operational standpoint, this integrated system is no more complex than other activated sludge system and operator attention requirements were minimal. secondly, due to floating force caused by captured air, the mechanical loading was reduced and energy would be saved.
650 0 _aSewage
_xPurification
_xBiological treatment
650 0 _aSewage
_xPurification
_xActivated sludge process
700 0 _aSamorn Muttamara,
_eChairperson
700 0 _aChongrak Polprasert,
_eExamination Committee
700 0 _aKasemsun Suwarnarat,
_eExamination committee
710 2 _aBES Engineering Corporation Taiwan, Rep. of China,
_eScholarship donor
810 2 _aAsian Institute of Technology.
_tThesis ;
_vno. EV-91-5
856 _3Full-Text
_uhttp://203.159.5.9/ait-thesis/detail.php?q=B17393
907 _a.b10366325
_bmnait
_cx
902 _a240402
998 _b2
_c951012
_dm
_ea
_fx
_g0
945 _lmnait
945 _lmnait
945 _lmnarc
942 _c22
942 _c40
942 _c20
909 _aBarcode : 30050120124622
_bCREATED : 2014-03-28
_cRECORD # : i12781484
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
909 _aBarcode : 30050120222673
_bCREATED : 2016-11-05
_cRECORD # : i1297433x
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
909 _aBarcode : 30050121074453
_bCREATED : 2023-03-23
_cRECORD # : i13440329
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
999 _c61580
_d61580