000 03772nas a2200421 4500
005 20260818143652.0
008 980904s1998 th uu m rtt 0| a1eng
035 _a.b11723737
099 9 _aAIT Thesis no. GE-97-14
100 0 _aTheera Wongsawanon
245 1 0 _aInteraction between hexagonal wire mesh reinforcement and silty sand backfill
260 _aBangkok :
_bAsian Institute of Technology,
_c1998
300 _a141, A-6, B-2 leaves :
_bill.
490 1 _aThesis ;
_vno. GE-97-14
500 _aA thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering, School of Civil Engineering
502 _aThesis (M.Eng.) - Asian Institute of Technology
520 _aThe mechanism governing soil reinforcement interaction has been simplified into two: soil sliding along the interface and pullout of reinforcement from the soil. The pullout tests have been commonly used for the investigation of pullout mechanism. To formulate the pullout resistance, pullout tests were conducted on hexagonal wire mesh embedded in silty sand locally known as Ayutthaya sand. Two types of wire mesh were tested, one is galvanized having a small aperture with dimension of 80 mm x 60 mm while the other is galvanized with additional PVC sleeve having larger aperture with dimension of 100 mm x 80 mm. The tests were conducted under normal pressure ranging from 3.50 to 9.10 t/m2 and pulled at a rate of Imm/min. In addition, the test results from previous investigators related to this study were also used. The results from this study revealed that the failure mechanism of both types of the reinforcement are different depending on the cell size aperture, reinforcement stiffness, reinforcement material, fill material, and vertical normal stress. The total pullout resistance of hexagonal wire mesh reinforcement contains two components, namely: friction and bearing resistance. The bearing resistance is higher than the friction resistance for both types of reinforcement. The applied normal pressure has an influence on both the bearing and friction resistance. The higher the normal pressure, the higher the friction and bearing resistance. Besides, the friction and bearing resistance mobilized on the galvanized wire mesh is greater than the PVC-coated wire mesh due to greater number of longitudinal and transverse member. The proposed analytical method of predicting the pullout-displacement relationship agreed with the test results reasonably well.
650 0 _aSoil-structure interaction
700 1 _aBergado, Dennes T.,
_eChairperson
700 1 _aLin, Der Guey,
_eCo-chairperson
700 1 _aShibuya, Satoru,
_eExamination Committee
700 1 _aKohgo, Yuji,
_eExamination Committee
710 2 _aThe Keidanren Foundation,
_eScholarship Donor
810 2 _aAsian Institute of Technology.
_tThesis ;
_vno. GE-97-14
856 _3Full-Text
_uhttp://203.159.5.9/ait-thesis/detail.php?q=B12818
907 _a.b11723737
_bmnait
_cx
902 _a240405
998 _b0
_c980904
_dm
_ea
_fx
_g0
945 _lmnait
945 _lmnait
945 _lmnarc
942 _c20
942 _c40
909 _aBarcode : 30050120717573
_bCREATED : 1997-07-04
_cRECORD # : i12091388
_dLPATRON : 1015674
_eLCHKIN : 2003-02-15
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 16
_jTOT RENEW : 10
909 _aBarcode : 30050120717557
_bCREATED : 1997-07-04
_cRECORD # : i1209139x
_dLPATRON : 1015662
_eLCHKIN : 2003-02-07
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 15
_jTOT RENEW : 10
909 _aBarcode : 30050160081120
_bCREATED : 2016-05-17
_cRECORD # : i12980456
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
999 _c61953
_d61953