000 03521nas|a2200397 i 4500
005 20260818144405.0
008 181100s2000 th u m rtt 00| a1eng d
035 _a.b11815711
099 9 _aAIT Thesis no.GE-99-07
100 0 _aChatchai Eurfur
245 1 0 _aInvestigations on factors affecting prefabricated vertical drain behaviour including discharge capacity and filter characteristic
260 _aBangkok :
_bAsian Institute of Technology,
_c2000
300 _a82, A-1 leaves
490 1 _aThesis ;
_vno. GE-99-07
520 _aThe series of laboratory tests have been conducted to investigate the effects of confining drain by clay and different thickness of rubber membrane on discharge capacity of prefabricated vertical drain (PVD). There are two types of PVD were tested namely: Mebra drain and CN drain. The test results indicate that confining the drain by thick rubber membrane is higher discharge capacity than thin rubber membrane confinement. Due to the tension stiffness of rubber membrane, the filter cannot be deform freely as that in clay. When confining the PVD with clay, the discharge capacity yielded much lower discharge capacity than rubber confinement. In addition, the clay particles can enter the drainage channel and the filter jacket can squeeze into the flow channel and further reduce the water flow. From the test results, Mebra drain consistently yielded the higher discharge capacity than CN drain because filter jacket of Mebra drain has higher tensile strength than CN drain. Thus, the tensile strength of filter jacket significantly affect the discharge capacity of PVD. In addition, the field test was constructed in AIT campus using the PVD to recharge and remove the negative piezometric drawdown. The PVD was installed to 10 m below the original ground level in square pattern with 1mx1 m spacing. The sand embankment which served as drainage blanket and construction platform, was constructed to a height of 1.2 m. The piezometric level in PVD area increased and removed the negative drawdown within 28 days after PVD installation. The PVD has successfully removed the negative drawdown in the subsoil. The maximum surface settlement 5.5 mm was observed at 130 days after installation. The settlement prediction by agreed with the field settlement.
500 _aA thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering, School of Civil Engineering
502 _aThesis (M.Eng.) - Asian Institute of Technology
650 0 _aVertical drains
700 1 _aBergado, Dennes T.,
_eChairperson
700 1 _a Guey. Lin Der,
_eExamination committee
700 1 _aBalasubramaniam, A.S.,
_eExamination Committee
700 1 _aMiura, Kinya,
_eExamination Committee
710 2 _aSelf-Support,
_eScholarship donor
810 2 _aAsian Institute of Technology.
_tThesis ;
_vno. GE-99-07
856 _3Full-Text
_uhttp://203.159.5.9/ait-thesis/detail.php?q=B06556
907 _a.b11815711
_bmnait
_cu
902 _a240401
998 _b0
_c001118
_dm
_ea
_fu
_g0
945 _lmnait
945 _lmnarc
942 _c22
942 _c40
909 _aBarcode : 30050120716740
_bCREATED : 2014-03-26
_cRECORD # : i12780017
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
909 _aBarcode : 30050160080965
_bCREATED : 2016-05-17
_cRECORD # : i12980249
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
999 _c64922
_d64922