| 000 | 03806nam a2200433 4500 | ||
|---|---|---|---|
| 005 | 20260817162919.0 | ||
| 008 | 011298s1988 th r 0000|00eng d | ||
| 035 | _a.b10088295 | ||
| 099 | 9 | _aAIT Thesis no. EV-88-5 | |
| 100 | 1 | _aChen, Chilung | |
| 245 | 1 | 0 | _aApplication of microfiltration in water and wastewater treatment |
| 260 |
_aBangkok : _bAsian Institute of Technology, _c1988 |
||
| 300 | _a90 p. | ||
| 490 | 1 |
_aThesis ; _vno. EV-88-5 |
|
| 500 | _aA thesis submitted in partial fulfilment of the requirement for the degree of Master of Engineering, School of Environment, Resources and Development | ||
| 502 | _aThesis (M.Eng.) - Asian Institute of Technology, 1988 | ||
| 520 | _aThe cross-flow membrane filtration techniques like ultrafiltration (UF) and microfiltration (MF) are useful in removing macromolecules, colloids and suspended solids. Unlike in standard filtration techniques, in cross-flow filtration, since the direction of the feed flow is tangential to the filter surface, accumulation of the filtered solids on the filter medium can be minimized by shearing action of flow. This study was divided into two parts: a) water treatment and b) wastewater treatment by using microfiltration technique. In water treatment, a study was c9nducted to determine the efficiency of MF as disinfecting unit and its applicability in the disinfection process of water treatment system. It was found out that correct choice of membrane size could achieve 100% E.Coli removal efficiency. Similarly, study performed showed that correct choice of cross-flow velocity and transmembrane pressure are very essential in the techno-economical optimization of this process. In wastewater treatment, AIT sewage was used as wastewater to be treated. A pretreatment using on-line flocculation arrangement can further improve the performance, while leading to a significant increase in permeate flux. Thus, in this study the possibility of using MF unit (with on-line flocculation arrangement) as household sewage treatment was investigated. It was found out that correct choice of membrane size, alum dose and crossflow velocity were very important. This treatment achieved not only high COD removal but also very high color and E.Coli removal. Experiments were conducted with various kinds of membrane pore sizes, different suspensions and different operating parameters like cross flow velocity, pressure difference etc. | ||
| 650 | 0 |
_aWater _xPurification _xFiltration |
|
| 650 | 0 |
_aSewage _xPurification _xFiltration |
|
| 700 | 1 |
_aVigneswaran, Saravanamuthu, _eChairperson |
|
| 700 | 1 |
_aI, Fude, _eExamination Committee |
|
| 700 | 1 |
_aYamamoto, Kazuo, _eExamination Committee |
|
| 700 | 0 |
_aKriengsak Udomsinrot, _eExamination Committee |
|
| 710 | 2 |
_aChina Technical Consultants Inc. Republic of China, _eScholarship Donor |
|
| 810 | 2 |
_aAsian Institute of Technology. _tThesis ; _vno. EV-88-5 |
|
| 856 |
_3Full-Text _uhttp://203.159.5.9/ait-thesis/detail.php?q=B18875 |
||
| 907 |
_a.b10088295 _bmnait _cx |
||
| 902 | _a240410 | ||
| 998 |
_b2 _c951012 _dm _ea _fx _g0 |
||
| 945 | _lmnait | ||
| 945 | _lmnait | ||
| 945 | _lmnarc | ||
| 942 | _c20 | ||
| 942 | _c40 | ||
| 909 |
_aBarcode : 30050003044228 _bCREATED : 1994-05-16 _cRECORD # : i10094106 _dLPATRON : 1019739 _eLCHKIN : 2006-11-19 _f# RENEWALS : 0 _g# OVERDUE : 0 _hIUSE3 : 0 _iTOT CHKOUT : 1 _jTOT RENEW : 1 |
||
| 909 |
_aBarcode : 30050003044236 _bCREATED : 1994-05-16 _cRECORD # : i10094118 _dLPATRON : 1016397 _eLCHKIN : 2003-05-03 _f# RENEWALS : 0 _g# OVERDUE : 0 _hIUSE3 : 0 _iTOT CHKOUT : 3 _jTOT RENEW : 0 |
||
| 909 |
_aBarcode : 30050120223606 _bCREATED : 2016-10-05 _cRECORD # : i12973415 _dLPATRON : 0 _eLCHKIN : - _f# RENEWALS : 0 _g# OVERDUE : 0 _hIUSE3 : 0 _iTOT CHKOUT : 0 _jTOT RENEW : 0 |
||
| 999 |
_c6704 _d6704 |
||