000 03879cas|a2200421 i 4500
005 20260817162954.0
008 230399s1993 th uzm rtt 00| a1eng d
035 _a.b10089238
099 9 _aAIT Thesis no.EV-93-26
100 1 _aWerellagama, D. R. Induka B.
245 1 0 _aApplication of the floto filter unit for contact flocculation filtration of surface waters
260 _aBangkok :
_bAsian Institute of Technology,
_c1993
300 _a141 leaves +
_e1 online resource
490 1 _aThesis ;
_vno. EV-93-26
500 _aA thesis submitted in partial fulfillment of the requirement for the degree of Master of Engineering
502 _aThesis (M.Eng.) - Asian Institute of Technology, 1993
520 _aLaboratory scale experiments were carried out in contact flocculation filtration using a dual media filter. The objective of the research was to find an optimum synthetic media combination which would give acceptable quality water under varying conditions while maintaining a low headloss. The media was lighter than water hence the bed was floating. Since coarse media remained at the bottom the flow direction was upflow which had the added advantage that the flow was in the direction of grain compression. Polypropylene and Polystyrene were selected as the optimum combination of media which due to their large . density difference did not intermix even under severe agitation. Spherical fine media performed better than angular fine media giving lower headloss and better effluent quality. The dual media combination and the higher rates of filtration are in line with the current trends in the water industry. The influent concentrations were kept constant and the flow velocity and filter media size were varied. The headloss variation along the filter, the influent quality to the two filter layers and the effluent quality were studied. The filter performed for over 40 hours producing acceptable quality water at conventional rapid sand filtration rates, also having low headloss development. Another major advantage was the ease and economy in backwashing. The filter media did not mix even during or after backwashing, thereby eliminating the most common problem encountered in conventional multi media filters. The Floto Filter operation was compared with upflow sand filtration. The headloss development curves for Floto filter showed a characteristic shape easily identifiable from that for sand. The existing mathematical model was able to predict the headloss profile but the concentration profile was not predicted. The necessity of particle size data for mathematical modelling of filtration of heterodisperse suspensions is emphasized.
650 0 _aWater
_xPurification
_xFiltration
700 1 _aVisvanathan, C.,
_eChairperson
700 1 _aFujii, Shigeo,
_eExamination committee
700 0 _aSamorn Muttamara,
_eExamination Committee
710 2 _aSwedish International Development Agency (SIDA),
_eScholarship donor
810 2 _aAsian Institute of Technology.
_tThesis ;
_vno. EV-93-26
856 _3Full-Text
_uhttp://203.159.5.9/ait-thesis/detail.php?q=B16676
907 _a.b10089238
_bmnait
_cx
902 _a240411
998 _b2
_c951012
_dm
_ea
_fx
_g0
945 _lmnait
945 _lmnait
945 _lmnarc
942 _c20
942 _c22
942 _c40
909 _aBarcode : 30050120806087
_bCREATED : 1994-05-16
_cRECORD # : i10095366
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
909 _aBarcode : a
_bCREATED : 1995-10-13
_cRECORD # : i10095378
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
909 _aBarcode : 30050160055728
_bCREATED : 2016-11-05
_cRECORD # : i12975187
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
999 _c6880
_d6880