245 1 2 _aA model energy performance standard for commercial buildings in Bangladesh
260 _aBangkok :
_bAsian Institute of Technology,
_c1994
300 _a138 leaves
490 1 _aThesis ;
_vno. ET-94-8
500 _aA thesis submitted in partial fulfillment of the requirement for the degree of Master of Engineering, School of Environment, Resources and Development
502 _aThesis (M.Eng.) - Asian Institute of Technology, 1994
520 _aEnergy conservation is an important concept for reducing energy consumption throughout the world. For any country application of this concept to the energy intensive sectors produces remarkable result. Modern buildings are one of the most energy consuming sector for most of the countries. This study focused only on the external heat gain part of total cooling load of a mechanically cooled building which consumes significant amount of energy. For the calculation of building envelope performance hourly meteorological data for the year 1990 has been used. Some computer program written in Turbo Basic is used for this analysis. Thermal properties and mass of wall are considered for this analysis. By varying the wall thickness, material, absorptivity of wall surface equivalent temperature difference were calculated for four different facades. Solar factor for eight different facades were calculated for four different angle of inclination of the surface. With different configuration three common types of shading devices namely Horizontal overhangs, Vertical fins, and Egg crate were analyzed to determine the effectiveness of those shading device on fenestration. Shading coefficient produced by those configuration were calculated. To improve the Overall Thermal Transfer Value (OTTV) of a building three different alternatives like improvement of glazing materials, reduction of window to wall ratio and insulation of opaque wall were analyzed. Since the roofs are well insulated for damp proofing purpose, and use of sky-lights are very uncommon, the Roof Thermal Transfer Value (RTTV) for typical roofs is very small. Therefore in this study much attention was given to the wall section of building. To identify the most energy efficient walls configuration for Bangladesh, Brick and Concrete walls of different thicknesses and effect of insulation thickness on heat transfer were considered. And also the effect of relative position of the wall mass and insulation were studied. For this analysis a model hypothetical building similar to typical buildings in Bangladesh was used to calculate the OTTV and to see the effect of different alternatives on it. The above mentioned alternatives were applied to observed the improvement of OTTV of the typical case. A simple calculation for annual electrical energy consumption were performed to see the benefit of implementing the building energy performance standard. Applying the calculated values of different parameters of OTTV from this analysis, present OTTV of typical building in Dhaka was determined by using the configuration data of an existing building.
650 0 _aCommercial buildings
_xBangladesh
_xEnergy conservation
700 0 _aSurapong Chiraratananon,
_eChairperson
700 1 _aKarmazsin, Etienne,
_eExamination Committee
700 1 _aDang, Giap Van,
_eExamination Committee
710 2 _aThe Government of Japan,
_eScholarship Donor
810 2 _aAsian Institute of Technology.
_tThesis ;
_vno. ET-94-8
856 _3Full-Text
_uhttp://203.159.5.9/ait-thesis/detail.php?q=B17933
907 _a.b10447593
_bmnait
_ct
902 _a240402
998 _b1
_c960214
_dm
_ea
_ft
_g2
945 _lmnait
945 _lmnait
945 _lmnarc
942 _c20
942 _c40
909 _aBarcode : 30050002933314
_bCREATED : 1994-07-13
_cRECORD # : i11703957
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
909 _aBarcode : 30050004739354
_bCREATED : 1994-07-13
_cRECORD # : i11703969
_dLPATRON : 1009761
_eLCHKIN : 1999-07-08
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 6
_jTOT RENEW : 1
909 _aBarcode : 30050120367270
_bCREATED : 2016-06-13
_cRECORD # : i13033219
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
999 _c77373
_d77373