| 000 | 03793nas|a2200385 i 4500 | ||
|---|---|---|---|
| 005 | 20260818155516.0 | ||
| 008 | 220200s1999 th uu m rtt 0| a1eng d | ||
| 035 | _a.b1177745x | ||
| 099 | 9 | _aAIT Thesis no.ET-99-16 | |
| 100 | 1 | _aPiyaratne, K. K. A. P. | |
| 245 | 1 | 0 | _aModeling building energy performance and establishing energy standards for commercial buildings in Sri Lanka |
| 260 |
_aBangkok : _bAsian Institute of Technology, _c1999 |
||
| 300 | _a142 leaves | ||
| 490 | 1 |
_aThesis ; _vno. ET-99-16 |
|
| 500 | _aA thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering. School of Environment Resources and Development | ||
| 502 | _aThesis (M.Eng.) - Asian Institute of Technology, 1999 | ||
| 520 | _aEnd use Energy of modem commercial buildings is significantly high. Due to lack of energy efficient envelopes of buildings, a large amount of energy is wasted. The understanding of thermal interaction in an air-conditioned building have become a necessity in the aspect of providing comfort as well as for rational use of energy. The most significant cause of high-energy consumption in air-conditioned building in tropical countries is heat transfer through the building envelope. Obviously, the better a building is insulated, the smaller will be tht! heat gain and losses through the structural elements. The high ambient temperature and solar radiation are the main driving forces for the heat transfer through the building envelope in air-conditioned buildings. But such transfer is modulated by the fabric of the envelope components attributed by their thermal properties. Both the driving forces for the heat transfer and the building usage are dynamic processes. It has been proved that the best way to regulate the thermal performances of building envelope for energy conservation is developing the building energy performance standards for buildings envelope for particular climatic area. A well-developed computer program; DOE-2, was utilized as the main research tool. Using the simulation program a model has been developed to represent the energy performance of the buildings category for the study of standards development. The OTTV formulation comprises parameter terms relating to the driving forces, the thermal properties of the building fabric, and the usage schedule of the building. Monthly parameter values ofOTTV formulation and the monthly OTTV values are developed and assessed. Development and assessment of steady-state indicators of cooling requirement for commercial buildings in Sri Lanka are also worked out. Cooling-degree hour, dry-bulb temperature and enthalpy of ambient air are all shown to be good indicators, but cooling degree hour is practically more significant. | ||
| 650 | 0 |
_aCommercial buildings _xEnergy conservation _zSri Lanka |
|
| 700 | 0 |
_aSurapong Chiraratananon, _eChairperson |
|
| 700 | 1 |
_aDhadbanjan, Thukaram, _eExamination Committee |
|
| 700 | 1 |
_aPham, H.L., _eExamination Committee |
|
| 710 | 2 |
_aGovernment of Sri Lanka, _eScholarship donor |
|
| 810 | 2 |
_aAsian Institute of Technology. _tThesis ; _vno. ET-99-16 |
|
| 856 |
_3Full-Text _uhttp://203.159.5.9/ait-thesis/detail.php?q=B12780 |
||
| 907 |
_a.b1177745x _bmnait _cu |
||
| 902 | _a240421 | ||
| 998 |
_b0 _c000222 _dm _ea _fu _g0 |
||
| 945 | _lmnait | ||
| 945 | _lmnarc | ||
| 942 | _c22 | ||
| 942 | _c40 | ||
| 909 |
_aBarcode : 30050120731988 _bCREATED : 2014-03-02 _cRECORD # : i12754754 _dLPATRON : 0 _eLCHKIN : - _f# RENEWALS : 0 _g# OVERDUE : 0 _hIUSE3 : 0 _iTOT CHKOUT : 0 _jTOT RENEW : 0 |
||
| 909 |
_aBarcode : 30050120365514 _bCREATED : 2016-06-15 _cRECORD # : i13037043 _dLPATRON : 0 _eLCHKIN : - _f# RENEWALS : 0 _g# OVERDUE : 0 _hIUSE3 : 0 _iTOT CHKOUT : 0 _jTOT RENEW : 0 |
||
| 999 |
_c77538 _d77538 |
||