| 000 | 03460nas|a2200397 i 4500 | ||
|---|---|---|---|
| 005 | 20260818170729.0 | ||
| 008 | 211099s1999 th uu m rtt 00| a1eng d | ||
| 035 | _a.b11764442 | ||
| 099 | 9 | _aAIT Thesis no.IP-99-03 | |
| 100 | 0 | _aNguyen Van Quoc | |
| 245 | 1 | 0 |
_aOptimal design strategies for extending water supply distribution networks : _ban application in Ho Chi Minh City - Vietnam |
| 260 |
_aBangkok : _bAsian Institute of Technology, _c1999 |
||
| 300 | _a51 leaves | ||
| 490 | 1 |
_aThsiss ; _vno. IP-99-03 |
|
| 500 | _aA thesis submitted in partial fulfillment of the requirement for the degree of Master of Engineering, School of Civil Engineering | ||
| 502 | _aThesis (M.Eng.) - Asian Institute of Technology, 1999 | ||
| 520 | _aNewly developed areas need new water supply systems. A new system is usually connected to the existing system for improving its supply capacities. The main objectives of the new system design are the maximum water supply capacities of the whole system including old and new network with the minimum exchange flow for available demand pattern. In this study, a basic model including hydraulic simulation, cost design such as pipe capital, operation cost and pump investment is modified from previous works and further developed. The so-called optimal or minimum cost design of water distribution systems has been approached. This model can be used to design completely new water systems. However, for the water system expansion problem this model has some disadvantages. Therefore, a revised model is proposed to solve this problem. These models are applied for extending water system in Ho Chi Minh City of Vietnam. The existing system has capacity of 600,000 m3 Id. Its distribution network consists of 574,000m of pipelines ND150 to ND 2000mm that still service 243,500 of customer connections. The new system requires capacity of 300,000m3 /day with one more water source, two booster stations and about 100,000m of primary pipelines connected to the existing system. The primary network of the whole system includes 31 nodes, 43 links, 2 water sources and 3 booster stations. The model is solved by setting up a computer program with 95 variables, 244 bound conditions, 86 linear and 62 nonlinear constraints. The reasonable results of computer program running for design extending water supply system in HCMC have proved the applicability of the developed models. | ||
| 650 | 0 |
_aWater _xDistribution |
|
| 650 | 0 |
_aWater-supply engineering _zVietnam _zHo Chi Minh |
|
| 700 | 1 |
_aNguyen Luong Bach, _eChairperson |
|
| 700 | 1 |
_aFujiwara, Okitsugu, _eExamination committee |
|
| 700 | 1 |
_aHa, Sung Ryong, _eExamination committee |
|
| 710 | 2 |
_aGovernment of Japan, _eScholarship donor |
|
| 810 | 2 |
_aAsian Institute of Technology. _tThesis ; _vno. IP-99-03 |
|
| 856 |
_3Full-Text _uhttp://203.159.5.9/ait-thesis/detail.php?q=B12349 |
||
| 907 |
_a.b11764442 _bmnait _cy |
||
| 902 | _a250824 | ||
| 998 |
_b0 _c991021 _dm _ea _fy _g0 |
||
| 945 | _lmnait | ||
| 945 | _lmnarc | ||
| 942 | _c22 | ||
| 942 | _c40 | ||
| 909 |
_aBarcode : 30050120730774 _bCREATED : 2014-03-20 _cRECORD # : i12775332 _dLPATRON : 0 _eLCHKIN : - _f# RENEWALS : 0 _g# OVERDUE : 0 _hIUSE3 : 1 _iTOT CHKOUT : 0 _jTOT RENEW : 0 |
||
| 909 |
_aBarcode : 30050160072228 _bCREATED : 2016-04-27 _cRECORD # : i12959078 _dLPATRON : 0 _eLCHKIN : - _f# RENEWALS : 0 _g# OVERDUE : 0 _hIUSE3 : 0 _iTOT CHKOUT : 0 _jTOT RENEW : 0 |
||
| 999 |
_c83753 _d83753 |
||