000 03460nas|a2200397 i 4500
005 20260818170729.0
008 211099s1999 th uu m rtt 00| a1eng d
035 _a.b11764442
099 9 _aAIT Thesis no.IP-99-03
100 0 _aNguyen Van Quoc
245 1 0 _aOptimal design strategies for extending water supply distribution networks :
_ban application in Ho Chi Minh City - Vietnam
260 _aBangkok :
_bAsian Institute of Technology,
_c1999
300 _a51 leaves
490 1 _aThsiss ;
_vno. IP-99-03
500 _aA thesis submitted in partial fulfillment of the requirement for the degree of Master of Engineering, School of Civil Engineering
502 _aThesis (M.Eng.) - Asian Institute of Technology, 1999
520 _aNewly developed areas need new water supply systems. A new system is usually connected to the existing system for improving its supply capacities. The main objectives of the new system design are the maximum water supply capacities of the whole system including old and new network with the minimum exchange flow for available demand pattern. In this study, a basic model including hydraulic simulation, cost design such as pipe capital, operation cost and pump investment is modified from previous works and further developed. The so-called optimal or minimum cost design of water distribution systems has been approached. This model can be used to design completely new water systems. However, for the water system expansion problem this model has some disadvantages. Therefore, a revised model is proposed to solve this problem. These models are applied for extending water system in Ho Chi Minh City of Vietnam. The existing system has capacity of 600,000 m3 Id. Its distribution network consists of 574,000m of pipelines ND150 to ND 2000mm that still service 243,500 of customer connections. The new system requires capacity of 300,000m3 /day with one more water source, two booster stations and about 100,000m of primary pipelines connected to the existing system. The primary network of the whole system includes 31 nodes, 43 links, 2 water sources and 3 booster stations. The model is solved by setting up a computer program with 95 variables, 244 bound conditions, 86 linear and 62 nonlinear constraints. The reasonable results of computer program running for design extending water supply system in HCMC have proved the applicability of the developed models.
650 0 _aWater
_xDistribution
650 0 _aWater-supply engineering
_zVietnam
_zHo Chi Minh
700 1 _aNguyen Luong Bach,
_eChairperson
700 1 _aFujiwara, Okitsugu,
_eExamination committee
700 1 _aHa, Sung Ryong,
_eExamination committee
710 2 _aGovernment of Japan,
_eScholarship donor
810 2 _aAsian Institute of Technology.
_tThesis ;
_vno. IP-99-03
856 _3Full-Text
_uhttp://203.159.5.9/ait-thesis/detail.php?q=B12349
907 _a.b11764442
_bmnait
_cy
902 _a250824
998 _b0
_c991021
_dm
_ea
_fy
_g0
945 _lmnait
945 _lmnarc
942 _c22
942 _c40
909 _aBarcode : 30050120730774
_bCREATED : 2014-03-20
_cRECORD # : i12775332
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 1
_iTOT CHKOUT : 0
_jTOT RENEW : 0
909 _aBarcode : 30050160072228
_bCREATED : 2016-04-27
_cRECORD # : i12959078
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
999 _c83753
_d83753