100 0 _aAraya Wicheansan
245 1 0 _aOptimization of electrochemical disinfection technology for the treatment of liquid effluent from onsite sanitation systems
260 _aPathum Thani, Thailand :
_bAsian Institute of Technology,
_c2015
300 _a64 p. :
_bill. +
_e1 online resource
490 1 _aThesis ;
_vno. EV-15-30
500 _aA thesis submitted in partial fulfillment of the requirements for the degree of Master of Science in Environmental Engineering and Management
502 _aThesis (M.Sc.) - Asian Institute of Technology, 2015
520 _aCurrently, electrochemical disinfection system are being widely used to be highly effectiveness in killing of microorganism. However, its application for onsite sanitation system is rare. This research aims to optimize the performance of electrochemical disinfection system for treatment of liquid effluent from onsite sanitation systems and develop the kinetic model to validate in the blackwater. The pathogen inactivation rates were conducted in synthetic wastewater at different operation conditions of voltages (5 V and 12 V), distance between electrodes (1 cm and 2 cm) and electrolyte concentrations (43, 95, and 2000 mg/L) before develop inactivation kinetic model. pH, temperature, conductivity, and current density were observed to evaluated the affecting factor of electrochemical disinfection system. Then, the septic tank effluents were sampling to test in the intermittent experiment to optimize the performance of the electrochemical disinfection system and validation kinetic model with the actual toilet wastewater in the pilot scale. The results found that in case of low chloride concentrations, E.coli can be inactivated 1 log-reduction within an hour under 5 voltages at distance between electrodes of 1 cm with 0.0157 % NaCl and 6 log-reductions within 15 minutes under 12 voltages, exclude at distance between electrode 2 cm with 0% and 0.007% NaCl. On the other hand, if chloride concentration in the wastewater is high, current density is not significant. E.coli can be inactivated rapidly. Ascaris lumbricoides eggs cannot be inactivated by electrochemical disinfection system due to improper pH, in insufficient chlorine compounds in the water and inadequate the suitable temperature for inactivation. The significant factors on the performance of pathogen inactivation include a chloride concentration which is the main effect on pathogen inactivation, voltage (charge loading) and the operation time. On the other hand, distance between electrodes is the factor is not significant on the performance of pathogen inactivation. The optimum operating condition of electrochemical disinfection need the appropriate current density and minimize energy requirement. Weibull model was modified the relationship between current density and E.coli removal before convert in the first-order model to fit on the value of density and E.coli removal with R2. However, Observed data of E.coli log reduction in pilot scale was not fitted on the predicted E.coli log reduction from the model because of disrupting factors such as the scum layer, suspended solid in the wastewater.
650 0 _aElectrochemical analysis
650 0 _aDisinfection
650 0 _aWater
_xPurification
_xDisinfection
650 0 _aSanitation
_zThailand
700 0 _aThammarat Koottatep,
_eChairperson
700 1 _aShipin, Oleg V.,
_eExamination Committee
700 0 _aSompong Hirunmasuwan,
_eExamination committee
710 2 _aBill &Melinda Gates Foundation through the Sustainable Decentralized Wastewater Management in Developing Countries Project,
_eScholarship donor
710 2 _aRoyal Thai Government Fellowship,
_eScholarship donor
810 2 _aAsian Institute of Technology.
_tThesis ;
_vno. EV-15-30
856 _3Full-Text
_uhttp://203.159.5.9/ait-thesis/detail.php?q=B02624
907 _a.b12303975
_bmnait
_ct
902 _a240423
998 _b0
_c190403
_dm
_ea
_ft
_g0
962 _a000:001:PDF:b1230397:004021:0:0:0:0:0:0
_tClick to view Abstract
_vn
945 _lmnait
945 _lmnait
945 _lmnarc
942 _c20
942 _c40
909 _aBarcode : 30050120546410
_bCREATED : 2019-03-04
_cRECORD # : i13170727
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
909 _aBarcode : 30050120546386
_bCREATED : 2019-03-04
_cRECORD # : i13170739
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
909 _aBarcode : 30050120878102
_bCREATED : 2019-06-20
_cRECORD # : i13195153
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
999 _c84020
_d84020