000 03045nas a2200421 4500
005 20260818171116.0
008 271098s1981 th r 000| eng d
035 _a.b1048663x
099 9 _aAIT Thesis no.EV-81-14
100 1 _aLo, Yee Kin
245 1 0 _aOxygen transfer mechanism in rotating contactors
260 _aBangkok :
_bAsian Institute of Technology,
_c1981
300 _a66 leaves :
_bill.
490 1 _aThesis ;
_vno. EV-81-14
500 _aA thesis submitted in partial fulfillment of the requirements for the degree of Master of Science, School of Environment, Resources and Development
502 _aThesis (M.Sc.) - Asian Institute of Technology, 1981
520 _aBecause of its peculiar design, the rotating disc con tac tor is expected to be a different oxygen transfer system from other aeration devices. Evaluation of the oxygen supply of this particular system requires an insight into the mass transfer processes involved. In this thesis, a model of the oxygen transfer mechanism in rotating contactors is presented. Verification is made by comparison of experiment with theory on the results of rates of increase in oxygen concentrations of the bulk water. Accordingly, general equation which has been successfully employed for determining oxygen transfer coefficients is justified. This approach has not been followed by any previous workers before. The matching of aeration patterns from simulation and experiment validated the model, but, lower values of the transfer rates arise due to the neglection of surface aeration. Assumption of Cs as saturation concentration of oxygen in water in common practice is erroneous as applied to rotating contactors. Nevertheless, the error may be small and correlation of transfer coefficients so obtained with disc rotating velocity and radius is established.
650 0 _aSewage
_xPurification
_xRotating disc process
700 1 _aWatanabe, Yoshimasa,
_eChairperson
700 0 _aChongrak Polprasert,
_eCo-Chaiperson
700 1 _aLohani, B.N.,
_eExamination Committee
710 2 _aThe Keidanren, Japan,
_eScholarship Donor
810 2 _aAsian Institute of Technology.
_tThesis ;
_vno. EV-81-14
856 _3Full-Text
_uhttp://203.159.5.9/ait-thesis/detail.php?q=B21608
907 _a.b1048663x
_bmnait
_cx
902 _a250106
998 _b2
_c951012
_dm
_ea
_fx
_g0
945 _lmnait
945 _lmnait
945 _lmnarc
942 _c22
942 _c40
942 _c20
909 _aBarcode : 30050120655799
_bCREATED : 2014-04-02
_cRECORD # : i12756581
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
909 _aBarcode : 30050160084678
_bCREATED : 2016-04-05
_cRECORD # : i12968584
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
909 _aBarcode : 30050121075245
_bCREATED : 2023-03-16
_cRECORD # : i13438591
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
999 _c85055
_d85055