000 03878cas|a2200409 i 4500
005 20260818171925.0
008 230399s1994 th uzm rtt 00| a1eng d
035 _a.b10502774
099 9 _aAIT Thesis no. EV-94-09
100 1 _aGoel, Rajeev
245 1 0 _aPilot-scale trials for the anaerobic treatment of polyester fiber wastewater to evolve an on-line process control strategy
260 _aBangkok :
_bAsian Institute of Technology,
_c1994
300 _a114 leaves
490 1 _aThesis ;
_vno. EV-94-09
500 _aA thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering, School of Environment, Resources & Development
502 _aThesis (M.Eng.) - Asian Institute of Technology, 1994
520 _aThis experimental study was undertaken on two type of anaerobic pilot scale reactors installed in the premises of a synthetic fiber producing industry. Fixed bed and contact tank reactors of size 3500 l each were used in the study. Contact tank reactor was started by inoculating with sludge of septic tank origin. On the other hand, no seeding was used for the fixed bed reactor as it contained sludge because of its previous operation in treating slaughter house wastewater. Both, the reactors were operated under varying COD loading at different hydraulic retention time (HRT). During the failure of the reactor under higher loading, an increase in the concentration of propionic and butyric acid inside the reactors was observed. This is contemplated to be the major cause of process upset. The maximum organic loading of 2.2 kg COD/m3 .d at HRT of 4.5 days for the fixed bed and 1.3 kg COD/m3 .d at HRT of 7.8 were achieved under stable conditions. Poor immobilization of biomass in the contact tank as compared to the Fixed bed reactor was achieved and this resulted in difference in maximum achievable organic loadings. The batch activity tests are found to be an effective tool to assess the methanogenic activity of the sludge and predicting the state of the reactor. But, inadequate methods of assessing the biomass concentration inside the reactors are seen as a limitation. Simplified process control strategies for detecting the process changes are defined using major process parameters like COD loading, pH, Gas production rate and the concentration of Volatile Fatty Acids. But, these are seen to be inadequate as the proper control action are not defined to run the process optimally. An adaptive control strategy is developed which can be computerized for on-line monitoring and control of anaerobic processes for optimal operation. ยท'
650 0 _aSewage
_xPurification
_xBiological treatment
700 1 _aStoll, Uwe,
_eChairperson
700 1 _aWise, Donald L.,
_eExamination Committee
700 1 _aFujii, Shigeo,
_eExamination Committee
710 2 _aSwedish International Development Authority (SIDA), Sweden,
_eScholarship Donor
810 2 _aAsian Institute of Technology.
_tThesis ;
_vno. EV-94-09
856 _3Full-Text
_uhttp://203.159.5.9/ait-thesis/detail.php?q=B15612
907 _a.b10502774
_bmnait
_cx
902 _a240404
998 _b2
_c951012
_dm
_ea
_fx
_g0
945 _lmnait
945 _lmnait
945 _lmnarc
942 _c20
942 _c40
909 _aBarcode : 30050003047684
_bCREATED : 1994-05-18
_cRECORD # : i10630466
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
909 _aBarcode : 30050003047692
_bCREATED : 1994-05-18
_cRECORD # : i10630478
_dLPATRON : 1014316
_eLCHKIN : 2002-08-06
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 3
_jTOT RENEW : 2
909 _aBarcode : 30050160055512
_bCREATED : 2016-11-05
_cRECORD # : i12975370
_dLPATRON : 0
_eLCHKIN : -
_f# RENEWALS : 0
_g# OVERDUE : 0
_hIUSE3 : 0
_iTOT CHKOUT : 0
_jTOT RENEW : 0
999 _c88039
_d88039