| 245 | 1 | 0 | _aAssessment of a directly coupled wind-powered compression refrigeration system |
| 260 |
_aBangkok : _bAsian Institute of Technology, _c1982 |
||
| 300 | _ax, 87 p. | ||
| 490 | 1 |
_aThesis ; _vno. ET-82-4 |
|
| 500 | _aA thesis submitted in partial fulfillment of the requirements for the degree of Master of Science, School of Environment, Resources and Development | ||
| 502 | _aThesis (M.Sc.) - Asian Institute of Technology, 1982 | ||
| 520 | _aA variable speed compression refrigeration test set-up was designed and fabricated to investigate the feasibility of its direct coupling with compatible windmills. The system was experimented with in order to evaluate the effect of "cold production" with various power input patterns and to pinpoint those parameters that severely affect its desired cooling performance due to the instantaneous fluctuations and intermittent availability of power. Suggestions have been made at a later section for possible solutions to the problems encountered in direct coupling. In the indoor test set-up a variable speed thyristor controlled eddy current motor was used to simulate a few ideal windmill output patterns. An input/output port with analog-digital and digital-analog converters was tested and developed to interface with a Z-80 microcomputer. The microprocessor was programmed to: i. control the variable speed motor; ii. track the variations of different parameters critically with respect to time; iii. process the acquired data from various transducers. Finally an analytical procedure has Been described to assess the viability and applicability· of such a system for a specified refrigeration requirement at a site of known wind regime, It has been experimentally proved that such a system is feasible with a slight modification in its designing to withstand large fluctuations in the windspeed, and to preserve the additional cooling effect during strong winds for later usage during low-winds or no wind periods. As the condenser and the compressor irreversibilities increase with increasing compressor speed, suggestions have been incorporated to improve the heat transfer area and orientation to take advantage of the strong winds and increase the heat transfer rate. | ||
| 650 | 0 | _aWind power | |
| 650 | 0 |
_aRefrigeration and refrigerating machinery _xResearch |
|
| 700 | 1 |
_aWalter, Despiegelaere, Ir., _eChairperson |
|
| 700 | 0 |
_aPrida Wibulswas, _eExamination Committee |
|
| 700 | 1 |
_aExell, Robert H.B., _eExamination Committee |
|
| 700 | 1 |
_aBhattacharya, Sribas C., _eExamination Committee |
|
| 710 | 2 |
_aCarl Duisberg Gesellschaff (Federal Republic of Germany), _eScholarship Donor |
|
| 810 | 2 |
_aAsian Institute of Technology. _tThesis ; _vno. ET-82-4 |
|
| 856 |
_3Full-Text _uhttp://203.159.5.9/ait-thesis/detail.php?q=B21158 |
||
| 907 |
_a.b10098628 _bmnait _cx |
||
| 902 | _a240829 | ||
| 998 |
_b3 _c951012 _dm _ea _fx _g0 |
||
| 945 | _lmnait | ||
| 945 | _lmnait | ||
| 945 | _lmnait | ||
| 945 | _lmnarc | ||
| 942 | _c20 | ||
| 942 | _c40 | ||
| 909 |
_aBarcode : 30050003103461 _bCREATED : 1995-10-13 _cRECORD # : i10108890 _dLPATRON : 0 _eLCHKIN : - _f# RENEWALS : 0 _g# OVERDUE : 0 _hIUSE3 : 0 _iTOT CHKOUT : 0 _jTOT RENEW : 0 |
||
| 909 |
_aBarcode : 30050003103487 _bCREATED : 1995-10-13 _cRECORD # : i10108907 _dLPATRON : 0 _eLCHKIN : - _f# RENEWALS : 0 _g# OVERDUE : 0 _hIUSE3 : 0 _iTOT CHKOUT : 0 _jTOT RENEW : 0 |
||
| 909 |
_aBarcode : 30050003103479 _bCREATED : 1995-10-13 _cRECORD # : i10108919 _dLPATRON : 1023339 _eLCHKIN : 2012-07-26 _f# RENEWALS : 0 _g# OVERDUE : 0 _hIUSE3 : 0 _iTOT CHKOUT : 1 _jTOT RENEW : 0 |
||
| 909 |
_aBarcode : 30050120352710 _bCREATED : 2016-10-06 _cRECORD # : i13032203 _dLPATRON : 0 _eLCHKIN : - _f# RENEWALS : 0 _g# OVERDUE : 0 _hIUSE3 : 0 _iTOT CHKOUT : 0 _jTOT RENEW : 0 |
||
| 999 |
_c8950 _d8950 |
||