| 000 | 03463nam a2200409 4500 | ||
|---|---|---|---|
| 005 | 20260817163657.0 | ||
| 008 | 290998s1994 th r 0000|0 eng d | ||
| 035 | _a.b10099372 | ||
| 099 | 9 | _aAIT Thesis no. ET-94-6 | |
| 100 | 1 | _aLin, Wen-ping | |
| 245 | 1 | 3 | _aAn assessment of the daylighting potential in (Kaohsiung) Taiwan |
| 260 |
_aBangkok : _bAsian Institute of Technology, _c1994 |
||
| 300 | _a226 leaves +1 online resource | ||
| 490 | 1 |
_aThesis ; _vno. ET-94-6 |
|
| 500 | _aA thesis submitted m partial fulfillment of the requirement for the degree of Master of Engineering | ||
| 502 | _aThesis (M.Eng.) - Asian Institute of Technology, 1994 | ||
| 520 | _aThis study propose a design procedure for daylighting based on the use of a set of daylight factor curves produced for typical perimeter zones in Electrical Engineering Building (EE) in National Kaohsiung Institute of Technology with its windows. The cases considered include perimeter zones with different window/wall ratio in case study rooms derived from proposed radiation records of three years in Kaohsiung (1991 , 1992, 1993). The procedure is also applied to a case study building. Physical measurement were performed and the results were analyzed and presented. Statisdtical frequency distribution of exterior horizontal illumination were derived using efficacy factor and this values are used for calculation of daylight factor curve and contours. Based on this available illumination, required supplementary artificial lighting were calculated to satisfy a given lighting requirements. The significant use of energy consumption in temperate climate are heat transfer through window and wall into a room. For a typical room, material details of the case study building were used in computer program (in turbo-basic using finite difference method) to compute heat transfer value. Data of typical day (i.e. global and diffuse radiation and temperature) for summer and winter were used in computer program to calculate effective solar radiation. An output data (i.e. effective solar radiation) were used to calculate heat transfer through window. Based on the heat transfer values of window and wall, daylighting vs energy use for typical summer and winter day were calculated. | ||
| 650 | 0 |
_aDaylighting _xTaiwan _xKaohsiung |
|
| 700 | 0 |
_aSurapong Chiraratananon, _eChairperson |
|
| 700 | 1 |
_aBhattacharya, Sribas C., _eExamination Committee |
|
| 700 | 0 |
_aKarmazsin, Etienne, _eExamination Committee |
|
| 710 | 2 |
_aRet-Ser Engineering Agency (R.O.C.), _eScholarship Donor |
|
| 810 | 2 |
_aAsian Institute of Technology. _tThesis ; _vno. ET-94-6 |
|
| 856 |
_3Full-Text _uhttp://203.159.5.9/ait-thesis/detail.php?q=B16221 |
||
| 907 |
_a.b10099372 _bmnait _cx |
||
| 902 | _a240411 | ||
| 998 |
_b1 _c951210 _dm _ea _fx _g3 |
||
| 945 | _lmnait | ||
| 945 | _lmnait | ||
| 945 | _lmnarc | ||
| 942 | _c20 | ||
| 942 | _c40 | ||
| 909 |
_aBarcode : 30050003107231 _bCREATED : 1994-07-13 _cRECORD # : i1170391x _dLPATRON : 0 _eLCHKIN : - _f# RENEWALS : 0 _g# OVERDUE : 0 _hIUSE3 : 0 _iTOT CHKOUT : 0 _jTOT RENEW : 0 |
||
| 909 |
_aBarcode : 30050003107249 _bCREATED : 1994-07-13 _cRECORD # : i11703921 _dLPATRON : 0 _eLCHKIN : - _f# RENEWALS : 0 _g# OVERDUE : 0 _hIUSE3 : 0 _iTOT CHKOUT : 0 _jTOT RENEW : 0 |
||
| 909 |
_aBarcode : 30050120367296 _bCREATED : 2016-06-13 _cRECORD # : i13033190 _dLPATRON : 0 _eLCHKIN : - _f# RENEWALS : 0 _g# OVERDUE : 0 _hIUSE3 : 0 _iTOT CHKOUT : 0 _jTOT RENEW : 0 |
||
| 999 |
_c9418 _d9418 |
||