| 000 | 04977nas a2200469 a 4500 | ||
|---|---|---|---|
| 005 | 20260817163729.0 | ||
| 008 | 170220s2015 th uu|m rtt 0| a1eng d | ||
| 035 | _a.b12179346 | ||
| 099 | 9 | _aAIT Thesis no.WM-15-14 | |
| 100 | 1 | _aRahman, Abdul | |
| 245 | 1 | 0 | _aAssessment of water use and leakage reduction scenarios in the distribution network of AIT |
| 260 |
_aPathum Thani, Thailand : _bAsian Institute of Technology, _c2015 |
||
| 300 |
_a1 online resource (133 leaves) : _bill. |
||
| 490 | 1 |
_aThesis ; _vno. WM-15-14 |
|
| 500 | _aA thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering in Water Engineering and Management | ||
| 502 | _aThesis (M.Eng.) - Asian Institute of Technology, 2015 | ||
| 520 | _aAsian Institute of Technology (AIT), located in Bangkok, Thailand, is a multi-cultural and multi-nationality institute where more than 2,200 people study, work and live together as in a community. Water to AIT is supplied by PWA through AIT water supply system constructed in 1970. Since then, till now, lack of research in assessment of water supply system in terms of existing level of leakages. On other hand, increasingly growing rate of population, expected 9.6 billion by 2050, it is firm to keep constant the pattern of water consumption for any longer period. Therefore, this research is undertaken to assess the AIT-WSS by benchmarking community level (IWA-PIs) and through hydraulic modelling (Epanet 2.0) along with comparisons of various behavioral characteristics of water users (Such as: Nationality level, Community/Religion level, students vs staff & guests, etc).Various classification processes were carried out within AIT community in order to compare possible interesting water users with each other. Addition to this, Hydraulic Model for AIT-WSS was developed as a result of calibrating and validating the model by introducing obtained data of field measurements for two consecutive weeks, 24hrs (10 {u2013} 24 Dec, 2014) in six stations. The key findings, while comparing various water users, were that, various factors such as: Climatical condition, availability of facilities, Academic Holidays, Uncertainty in population, socioeconomic development, and other cultural activities: Christmas, Eid ul-Fitr, Holi, Songkran and etc. jointly effects the lpcd trend to be risen up and down. The key findings of hydraulic model shows that during peak demand, the low and high pressure zones ranges between 18 to 20, and 15.5 to 17.5 m of pressure head respectivelyand leakage level is 33.70% (30.70% by water balance). Various scenarios for leakage reduction were developed such as: Pipe Upgrading of high leakage zone (leakage level reduces to 31.74%), PRV introduction at inlet point (Leakage level reduces to 31.74%), combined of first two scenarios where Leakage level reduces to 20.6 percent and etc. Addition to this, five more scenarios related to introduction of various inlet pressure condition to the model developed and their respected results of all scenarios were compared with each other in conjunction with base scenario | ||
| 650 | 0 |
_aWater use _zAsian Institute of Technology (Thailand) |
|
| 700 | 1 |
_aBabel, Mukand Singh, _eChairperson |
|
| 700 | 1 |
_aShrestha, Sangam, _eExamination Committee |
|
| 700 | 0 |
_aSutat Weesakul, _eExamination Committee |
|
| 700 | 1 |
_aShinde, Victor, _eExamination Committee |
|
| 710 | 2 |
_aMinistry of Higher Education (MoHE)/Kandahar University, Afghanistan, _eScholarship Donor |
|
| 710 | 2 |
_aAIT Fellowship, _eScholarship Donor |
|
| 810 | 2 |
_aAsian Institute of Technology. _tThesis ; _vno. WM-15-14 |
|
| 856 |
_3Full-Text _uhttp://203.159.5.9/ait-thesis/detail.php?q=B04404 |
||
| 907 |
_a.b12179346 _bmnait _cm |
||
| 902 | _a240409 | ||
| 998 |
_b0 _c170220 _dm _ea _fm _g0 |
||
| 962 |
_a000:001:PDF:b1217934:002962:0:0:0:0:0:0 _tAbstract _vn |
||
| 945 | _lmnait | ||
| 945 | _lmnait | ||
| 945 | _lmnait | ||
| 945 | _lmnarc | ||
| 942 | _c20 | ||
| 942 | _c40 | ||
| 909 |
_aBarcode : 30050120341978 _bCREATED : 2017-02-20 _cRECORD # : i1306793x _dLPATRON : 1029074 _eLCHKIN : 2019-01-09 _f# RENEWALS : 0 _g# OVERDUE : 0 _hIUSE3 : 0 _iTOT CHKOUT : 1 _jTOT RENEW : 3 |
||
| 909 |
_aBarcode : 30050120342794 _bCREATED : 2017-02-20 _cRECORD # : i13067941 _dLPATRON : 1028055 _eLCHKIN : 2018-05-15 _f# RENEWALS : 0 _g# OVERDUE : 0 _hIUSE3 : 3 _iTOT CHKOUT : 2 _jTOT RENEW : 0 |
||
| 909 |
_aBarcode : 30050160040399 _bCREATED : 2018-01-17 _cRECORD # : i13114475 _dLPATRON : 0 _eLCHKIN : - _f# RENEWALS : 0 _g# OVERDUE : 0 _hIUSE3 : 0 _iTOT CHKOUT : 0 _jTOT RENEW : 0 |
||
| 909 |
_aBarcode : 30050120918890 _bCREATED : 2019-11-21 _cRECORD # : i13231686 _dLPATRON : 0 _eLCHKIN : - _f# RENEWALS : 0 _g# OVERDUE : 0 _hIUSE3 : 0 _iTOT CHKOUT : 0 _jTOT RENEW : 0 |
||
| 999 |
_c9559 _d9559 |
||