Effects of harmonics and voltage flickers on a power system in Samutprakarn province, Thailand

By: Call Number: AIT Thesis no.ET-99-29 Contributor(s): Material type: SeriesSeries: Asian Institute of Technology. Thesis ; no. ET-99-29Publication details: Bangkok : Asian Institute of Technology, 1999Description: 75 leavesSubject(s): Online resources: Dissertation note: Thesis (M.Eng.) - Asian Institute of Technology, 1999 Summary: In recent years, power quality becomes more critical because of the increase in the number of loads sensitive to power disturbances, and as the loads themselves have become major causes of the degradation of power quality. Therefore, power quality responsibility lies with three main groups: the utility company, the customer group, and the manufacturing group. A number of load types used in industries cause harmonic current and voltage fluctuation such as electric arc furnaces (EAFs) that are found in Steel Manufacturing Facility. Due to the arc furnace load, the significant voltage distortion will occur in power system, which effects the other customer in the same area. In the utility side, the system configuration also causes voltage distortion too. Simulation results from HI_ WA VE program show that the fifth harmonic resonance occurs in power system and by changing the configuration of capacitor bank at distribution feeders can solve this problem. Electric arc furnaces cause voltage fluctuation on account of the oscillated of reactive power. The field measurements illustrate the effect of this voltage fluctuation on another customers in the same distribution area. Consequencely, by adding the static VAR compensator at the steel manufacturing can reduced the flicker problem, which can be seen by the simulation results of EMTDC program.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Cover image Item type Current library Home library Collection Shelving location Call number Materials specified Vol info URL Copy number Status Notes Date due Barcode Item holds Item hold queue priority Course reserves
22-AIT Thesis (Replacement) Asian Institute of Technology Library AIT Publications AIT Thesis no.ET-99-29 (Browse shelf(Opens below)) 3 Available 30050120731871
40-Archives Asian Institute of Technology Library Archives AIT Thesis no.ET-99-29 (Browse shelf(Opens below)) Available 30050120365399

A thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering. School of Environment Resources and Development

Thesis (M.Eng.) - Asian Institute of Technology, 1999

In recent years, power quality becomes more critical because of the increase in the number of loads sensitive to power disturbances, and as the loads themselves have become major causes of the degradation of power quality. Therefore, power quality responsibility lies with three main groups: the utility company, the customer group, and the manufacturing group. A number of load types used in industries cause harmonic current and voltage fluctuation such as electric arc furnaces (EAFs) that are found in Steel Manufacturing Facility. Due to the arc furnace load, the significant voltage distortion will occur in power system, which effects the other customer in the same area. In the utility side, the system configuration also causes voltage distortion too. Simulation results from HI_ WA VE program show that the fifth harmonic resonance occurs in power system and by changing the configuration of capacitor bank at distribution feeders can solve this problem. Electric arc furnaces cause voltage fluctuation on account of the oscillated of reactive power. The field measurements illustrate the effect of this voltage fluctuation on another customers in the same distribution area. Consequencely, by adding the static VAR compensator at the steel manufacturing can reduced the flicker problem, which can be seen by the simulation results of EMTDC program.