A feasibility study on ice storage in an office building in Bangkok

By: Call Number: AIT Thesis no. ET-90-1 Contributor(s): Material type: TextSeries: Asian Institute of Technology. Thesis ; no. ET-90-1Publication details: Bangkok : Asian Institute of Technology, 1990Description: 159 pSubject(s): Online resources: Dissertation note: Thesis (M.Eng.) - Asian Institute of Technology, 1990 Summary: A feasibility study on ice storage in an office building in Bangkok, which has 24 floors in one block and 2 floors in another block, is described in this thesis. The ice storage under a partial and modified demand-limited design with constant proportion control are considered. It has been found from a preliminary results of an energy audit that the air conditioning system consumed about 61.1% of total building electrical energy consumption and chillers consumed about 51.8% of total electrical energy consumption in air-conditioning (A/C) system. The average coefficient of performance of the chillers is 4.77 at the daytime (450 ton chiller) and 3.45 at the nighttime (50 ton chiller) . The average system efficiency is 1.55 kW/ton. The DOE- 2. lC building energy analysis computer program was used to analyze the energy consumption in the studied building. Conventional heating ventilation air-conditioning (HVAC) system was compared to ice storage systems using simple payback periods, net present value and internal rate of return. It was found that at present electricity rate structure , partial storage is more economically feasible than other operating modes . But under a number of alternative time-of-day (TOD) rate structure, the modified demand-limited storage system present a better economic feasibility, especially when the energy charge for the off-peak period is differentiated from other period.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Cover image Item type Current library Home library Collection Shelving location Call number Materials specified Vol info URL Copy number Status Notes Date due Barcode Item holds Item hold queue priority Course reserves
20-AIT Publication Asian Institute of Technology Library AIT Publications AIT Thesis no. ET-90-1 (Browse shelf(Opens below)) 1 Available 30050003105292
20-AIT Publication Asian Institute of Technology Library AIT Publications AIT Thesis no. ET-90-1 (Browse shelf(Opens below)) 2 Available 30050003105284
40-Archives Asian Institute of Technology Library Archives AIT Thesis no. ET-90-1 (Browse shelf(Opens below)) Available 30050120344782

A thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering, School of Engineering and Technology

Thesis (M.Eng.) - Asian Institute of Technology, 1990

A feasibility study on ice storage in an office building in Bangkok, which has 24 floors in one block and 2 floors in another block, is described in this thesis. The ice storage under a partial and modified demand-limited design with constant proportion control are considered. It has been found from a preliminary results of an energy audit that the air conditioning system consumed about 61.1% of total building electrical energy consumption and chillers consumed about 51.8% of total electrical energy consumption in air-conditioning (A/C) system. The average coefficient of performance of the chillers is 4.77 at the daytime (450 ton chiller) and 3.45 at the nighttime (50 ton chiller) . The average system efficiency is 1.55 kW/ton. The DOE- 2. lC building energy analysis computer program was used to analyze the energy consumption in the studied building. Conventional heating ventilation air-conditioning (HVAC) system was compared to ice storage systems using simple payback periods, net present value and internal rate of return. It was found that at present electricity rate structure , partial storage is more economically feasible than other operating modes . But under a number of alternative time-of-day (TOD) rate structure, the modified demand-limited storage system present a better economic feasibility, especially when the energy charge for the off-peak period is differentiated from other period.