Analysis of MEMS based heparin infusion pump for wearable artificial kidney system (WAK) (Record no. 4875)

MARC details
000 -LEADER
fixed length control field 03808nam a2200445 a 4500
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20260817162405.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 140613s2010 th ad ||| |000 0 eng d
035 ## - SYSTEM CONTROL NUMBER
System control number .b12132032
099 #9 - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number AIT Thesis no.ISE-10-33
100 1# - MAIN ENTRY--PERSONAL NAME
Personal name Sheikh, Naveed
245 10 - TITLE STATEMENT
Title Analysis of MEMS based heparin infusion pump for wearable artificial kidney system (WAK)
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Pathum Thani :
Name of publisher, distributor, etc. Asian Institute of Technology,
Date of publication, distribution, etc. 2010
300 ## - PHYSICAL DESCRIPTION
Extent 58 p. :
Other physical details ill. (some col.), charts
490 1# - SERIES STATEMENT
Series statement Thesis ;
Volume/sequential designation no. ISE-10-33
500 ## - GENERAL NOTE
General note A thesis submitted in partial fulfillment of the requirements for the Degree of Master of ScienceinMechatronics, School of Engineering and Technology
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Eng.) - Asian Institute of Technology, 2010
520 ## - SUMMARY, ETC.
Summary, etc. Kidney failure is one of the major health problems around the world andincreasing continuously. The research forecastsan exponential growth in the kidney failureduring coming years.There are twoconventional treatments for end stage renal disease (ESRD) and acute renal failure (ARF) those are dialysis and inherent kidney transplant.After kidney transplant,the patient has to take expensive medicine for a long time.There are many limitations associated with the conventional treatment methods. To overcome the limitations of conventional treatment methods, MEMSbased hemodialysis machine or wearable artificial kidney (WAK) can beused.Themajor benefit of this technology is that thepatients can continue their work during dialysis. It isvery cheap and easy to operate.The basic objective of this research is to study the flow rate of available micropumps using different liquids (DI water, heparin, blood, etc) and find out the suitabledevice forwearable artificial kidney (WAK)or hemodialysis machine.The controlled electronic circuit is used to investigate the fluid flow rate through the micropump. The sine wave, rectangular wave and SRS signal have been used to operate the micropump. Numerical simulation of diaphragm of micropump has also been conducted using ANSYS tofind the deflection and stress distribution of membrane. This study gives useful information to develop the MEMSbased hemodialysis system.
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Microelectronmechanical systems
650 #0 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Acute renal failure
General subdivision Treatment
-- Computer simulation
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Afzulpurkar, Nitin V.,
Relator term Chairperson
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Manukid Parnichkun,
Relator term Examination Committee
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Mongkol Ekpanyapong,
Relator term Examination Committee
710 2# - ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element University of Balochistan, Quetta, Pakistan,
Relator term Scholarship donor
710 2# - ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Asian Institute of Technology Fellowship,
Relator term Scholarship donor
810 2# - SERIES ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Asian Institute of Technology.
Title of a work Thesis ;
Volume/sequential designation no. ISE-10-33
856 ## - ELECTRONIC LOCATION AND ACCESS
Materials specified Full-Text
Uniform Resource Identifier <a href="http://203.159.5.9/ait-thesis/detail.php?q=B03315 ">http://203.159.5.9/ait-thesis/detail.php?q=B03315 </a>
907 ## - LOCAL DATA ELEMENT G, LDG (RLIN)
a .b12132032
b mnait
c j
902 ## - LOCAL DATA ELEMENT B, LDB (RLIN)
a 240404
998 ## - LOCAL CONTROL INFORMATION (RLIN)
Operator's initials, OID (RLIN) 0
Cataloger's initials, CIN (RLIN) 140615
First date, FD (RLIN) m
-- a
-- j
-- 0
962 ## -
-- 000:001:PDF:b1213203:001384:0:0:0:0:0:0
-- Abstract--AIT Thesis no.ISE-10-33
-- n
945 ## - LOCAL PROCESSING INFORMATION (OCLC)
l mnait
945 ## - LOCAL PROCESSING INFORMATION (OCLC)
l mnait
945 ## - LOCAL PROCESSING INFORMATION (OCLC)
l mnarc
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type 20-AIT Publication
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type 40-Archives
909 ## - LOCAL ITEMS USED
Barcode Barcode : 30050120846406
CREATED CREATED : 2014-06-16
RECORD Id RECORD # : i12810368
LPATRON LPATRON : 1026647
LCHKIN LCHKIN : 2017-05-23
RENEWALS # RENEWALS : 0
-- # OVERDUE : 0
-- IUSE3 : 1
-- TOT CHKOUT : 1
-- TOT RENEW : 0
909 ## - LOCAL ITEMS USED
Barcode Barcode : 30050120331599
CREATED CREATED : 2014-06-16
RECORD Id RECORD # : i1281037x
LPATRON LPATRON : 1026564
LCHKIN LCHKIN : 2017-03-20
RENEWALS # RENEWALS : 0
-- # OVERDUE : 0
-- IUSE3 : 1
-- TOT CHKOUT : 1
-- TOT RENEW : 1
909 ## - LOCAL ITEMS USED
Barcode Barcode : 30050160030184
CREATED CREATED : 2016-03-16
RECORD Id RECORD # : i12893006
LPATRON LPATRON : 0
LCHKIN LCHKIN : -
RENEWALS # RENEWALS : 0
-- # OVERDUE : 0
-- IUSE3 : 0
-- TOT CHKOUT : 0
-- TOT RENEW : 0
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Shelving location Date acquired Cost, normal purchase price Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
      Available for Loans Asian Institute of Technology Library Asian Institute of Technology Library AIT Publications 17/08/2026 50.00   AIT Thesis no.ISE-10-33 30050120846406 17/08/2026 1 17/08/2026 20-AIT Publication
      Available for Loans Asian Institute of Technology Library Asian Institute of Technology Library AIT Publications 17/08/2026 50.00   AIT Thesis no.ISE-10-33 30050120331599 17/08/2026 2 17/08/2026 20-AIT Publication
      Available for Loans Asian Institute of Technology Library Asian Institute of Technology Library Archives 17/08/2026     AIT Thesis no.ISE-10-33 30050160030184 17/08/2026 1 17/08/2026 40-Archives
คัดลอกแล้ว!