Thermal diffusion in an estuary

By: Call Number: AIT Thesis no.WA-80-18 Contributor(s): Material type: TextSeries: Asian Institute of Technology. Thesis ; no. WA-80-18Publication details: Bangkok : Asian Institute of Technology, 1981Description: v, 80 pSubject(s): Online resources: Dissertation note: Thesis (M.Eng.) - Asian Institute of Technology, 1981 Summary: The warm water issuing from the 2,400 MW Bang Pakong Power Plant was investigated in the vicinity of the plant site under unsteady flow condition in a hydraulic model . Heat distribution in the far field and warm water recirculation to the pump intake were obtained. Reproduction of unsteady flow was made by a built-in tide generator, and the warm water generator distributed the pre-determined temperature to the outfall structure. Temperature distribution and warm water circulation due to the depression of outfall structure were also conducted. It was found that there was an effective temperature reduction due to lowering the elevation of outfall structure.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Cover image Item type Current library Home library Collection Shelving location Call number Materials specified Vol info URL Copy number Status Notes Date due Barcode Item holds Item hold queue priority Course reserves
22-AIT Thesis (Replacement) Asian Institute of Technology Library AIT Publications AIT Thesis no.WA-80-18 (Browse shelf(Opens below)) 3 Available 30050120572499
40-Archives Asian Institute of Technology Library Archives AIT Thesis no.WA-80-18 (Browse shelf(Opens below)) Available 30050160037890
20-AIT Publication Asian Institute of Technology Library AIT Publications AIT Thesis no.WA-80-18 (Browse shelf(Opens below)) 1 Available 30050121099088

A thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering, School of Engineering and Technology

Thesis (M.Eng.) - Asian Institute of Technology, 1981

The warm water issuing from the 2,400 MW Bang Pakong Power Plant was investigated in the vicinity of the plant site under unsteady flow condition in a hydraulic model . Heat distribution in the far field and warm water recirculation to the pump intake were obtained. Reproduction of unsteady flow was made by a built-in tide generator, and the warm water generator distributed the pre-determined temperature to the outfall structure. Temperature distribution and warm water circulation due to the depression of outfall structure were also conducted. It was found that there was an effective temperature reduction due to lowering the elevation of outfall structure.

There are no comments on this title.

to post a comment.
คัดลอกแล้ว!