Effectiveness of plastic media in removing turbidity in horizontal flow filter

By: Call Number: AIT Thesis no.EV-81-8 Contributor(s): Material type: Continuing resourceSeries: Asian Institute of Technology. Thesis ; no. EV-81-8Publication details: Bangkok : Asian Institute of Technology, 1981Description: 35 leaves : illSubject(s): Online resources: Dissertation note: Thesis (M.Eng.) - Asian Institute of Technology, 1981 Summary: A bench-scale horizontal filter was used to study the effectiveness of the plastic media as a filter media. The various parameters affecting the filter performances were studied and the transport mechanism was investigated. Experiments were conducted by varying raw water turbidities and flow rates. It was found that the plastic balls were efficient in removing suspended solids only in the range of 30 to 60%. The optimum flow rate for this removal of small particle of suspended solids was 1.5 m3/m2 h for the different levels of influent turbidities. For bigger particle size, the optimum flow rates were 0.5 m3/m2 h, 1.0 m3/m2 h and 1.5 m3/m2 h for influent turbidity levels of 150 FTU, 100 FTU and 50 FTU, respectively. The predominant transport mechanisms in this study were hydrodynamic action and gravity. The others mechanisms were not found to be significant
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Cover image Item type Current library Home library Collection Shelving location Call number Materials specified Vol info URL Copy number Status Notes Date due Barcode Item holds Item hold queue priority Course reserves
22-AIT Thesis (Replacement) Asian Institute of Technology Library AIT Publications AIT Thesis no.EV-81-8 (Browse shelf(Opens below)) 3 Available 30050120655856
40-Archives Asian Institute of Technology Library Archives AIT Thesis no.EV-81-8 (Browse shelf(Opens below)) Available 30050160084736
20-AIT Publication Asian Institute of Technology Library AIT Publications AIT Thesis no.EV-81-8 (Browse shelf(Opens below)) 1 Available 30050121075302

A thesis submitted in partial fulfillment of the requirements for the degree of Master of Engineering, School of Environment, Resources and Development

Thesis (M.Eng.) - Asian Institute of Technology, 1981

A bench-scale horizontal filter was used to study the effectiveness of the plastic media as a filter media. The various parameters affecting the filter performances were studied and the transport mechanism was investigated. Experiments were conducted by varying raw water turbidities and flow rates. It was found that the plastic balls were efficient in removing suspended solids only in the range of 30 to 60%. The optimum flow rate for this removal of small particle of suspended solids was 1.5 m3/m2 h for the different levels of influent turbidities. For bigger particle size, the optimum flow rates were 0.5 m3/m2 h, 1.0 m3/m2 h and 1.5 m3/m2 h for influent turbidity levels of 150 FTU, 100 FTU and 50 FTU, respectively. The predominant transport mechanisms in this study were hydrodynamic action and gravity. The others mechanisms were not found to be significant

There are no comments on this title.

to post a comment.
คัดลอกแล้ว!