A fuzzy logic system for minimization of harmonics under the unbalanced operation of static VAR compensators (Record no. 48495)

MARC details
000 -LEADER
fixed length control field 02943nas|a2200421 i 4500
005 - DATE AND TIME OF LATEST TRANSACTION
control field 20260818114755.0
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION
fixed length control field 280101s2000 th uu m rtt 00| a1eng d
035 ## - SYSTEM CONTROL NUMBER
System control number .b11818839
099 #9 - LOCAL FREE-TEXT CALL NUMBER (OCLC)
Classification number AIT Thesis no. ET-00-20
100 1# - MAIN ENTRY--PERSONAL NAME
Personal name Kumar, R. Arun
245 12 - TITLE STATEMENT
Title A fuzzy logic system for minimization of harmonics under the unbalanced operation of static VAR compensators
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Place of publication, distribution, etc. Bangkok :
Name of publisher, distributor, etc. Asian Institute of Technology,
Date of publication, distribution, etc. 2000
300 ## - PHYSICAL DESCRIPTION
Extent 70 leaves
490 1# - SERIES STATEMENT
Series statement Thesis ;
Volume/sequential designation no. ET-00-20
500 ## - GENERAL NOTE
General note A thesis submitted in partial fulfilment of the requirements for the degree of Master of Engineering
502 ## - DISSERTATION NOTE
Dissertation note Thesis (M.Eng.) - Asian Institute of Technology
520 ## - SUMMARY, ETC.
Summary, etc. In modern power systems, there has been a tremendous growth of single-phase non-linear loads supplied from 3-phase distribution systems, which generate unbalanced currents in the system. These non-linear loads cause poor power factor, low efficiency and interference with communication networks. To improve system performance, Thyristor Controlled Static VAR Compensators (SVCs) are already used in power systems, but they introduce additional harmonics in the AC system. The performance of SVCs are measured by, the Telephone Interference Factor (TIF), the Total Harmonic Current Factor (IT) and the Distortion Factor (D). To optimize the operation of SVCs, the unsymmetrical firing of thyristors is required. Fuzzy Logic Systems (FLSs) can be effectively used to control the firing angle of thyristors by using previous knowledge base and Fuzzy rule base with minimum source reactive power and harmonics injection in the power system. This report presents a Rule Based Fuzzy Logic approach to determine an optimum combination of the phase-wise reactive power generation from SVCs to achieve a balanced reactive power supply from AC system based on TIF.
650 10 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Fuzzy logic
650 10 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Electric power systems
General subdivision Control
700 0# - ADDED ENTRY--PERSONAL NAME
Personal name Surapong Chiraratananon,
Relator term Chairperson
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Dhadbanjan, Thukaram,
Relator term Chairperson
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Rajapakse, Athula,
Relator term Examination committee
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Yu, Cun Yi,
Relator term Examination Committee
710 2# - ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Partial Scholarship,
Relator term Scholarship donor
710 2# - ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element AIT,
Relator term Scholarship donor
810 2# - SERIES ADDED ENTRY--CORPORATE NAME
Corporate name or jurisdiction name as entry element Asian Institute of Technology.
Title of a work Thesis ;
Volume/sequential designation no. ET-00-20
856 ## - ELECTRONIC LOCATION AND ACCESS
Materials specified Full-Text
Uniform Resource Identifier <a href="http://203.159.5.9/ait-thesis/detail.php?q=B06806">http://203.159.5.9/ait-thesis/detail.php?q=B06806</a>
907 ## - LOCAL DATA ELEMENT G, LDG (RLIN)
a .b11818839
b mnait
c u
902 ## - LOCAL DATA ELEMENT B, LDB (RLIN)
a 240401
998 ## - LOCAL CONTROL INFORMATION (RLIN)
Operator's initials, OID (RLIN) 0
Cataloger's initials, CIN (RLIN) 010128
First date, FD (RLIN) m
-- a
-- u
-- 2
945 ## - LOCAL PROCESSING INFORMATION (OCLC)
l mnait
945 ## - LOCAL PROCESSING INFORMATION (OCLC)
l mnarc
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type 22-AIT Thesis (Replacement)
942 ## - ADDED ENTRY ELEMENTS (KOHA)
Koha item type 40-Archives
909 ## - LOCAL ITEMS USED
Barcode Barcode : 30050120748909
CREATED CREATED : 2013-11-20
RECORD Id RECORD # : i12747324
LPATRON LPATRON : 0
LCHKIN LCHKIN : -
RENEWALS # RENEWALS : 0
-- # OVERDUE : 0
-- IUSE3 : 0
-- TOT CHKOUT : 0
-- TOT RENEW : 0
909 ## - LOCAL ITEMS USED
Barcode Barcode : 30050120347397
CREATED CREATED : 2016-06-15
RECORD Id RECORD # : i13038217
LPATRON LPATRON : 0
LCHKIN LCHKIN : -
RENEWALS # RENEWALS : 0
-- # OVERDUE : 0
-- IUSE3 : 0
-- TOT CHKOUT : 0
-- TOT RENEW : 0
Holdings
Withdrawn status Lost status Damaged status Not for loan Home library Current library Shelving location Date acquired Cost, normal purchase price Total checkouts Full call number Barcode Date last seen Copy number Price effective from Koha item type
      Available for Loans Asian Institute of Technology Library Asian Institute of Technology Library AIT Publications 18/08/2026 50.00   AIT Thesis no. ET-00-20 30050120748909 18/08/2026 3 18/08/2026 22-AIT Thesis (Replacement)
      Available for Loans Asian Institute of Technology Library Asian Institute of Technology Library Archives 18/08/2026     AIT Thesis no. ET-00-20 30050120347397 18/08/2026   18/08/2026 40-Archives
คัดลอกแล้ว!