A fuzzy logic system for minimization of harmonics under the unbalanced operation of static VAR compensators

By: Call Number: AIT Thesis no. ET-00-20 Contributor(s): Material type: SeriesSeries: Asian Institute of Technology. Thesis ; no. ET-00-20Publication details: Bangkok : Asian Institute of Technology, 2000Description: 70 leavesSubject(s): Online resources: Dissertation note: Thesis (M.Eng.) - Asian Institute of Technology Summary: In modern power systems, there has been a tremendous growth of single-phase non-linear loads supplied from 3-phase distribution systems, which generate unbalanced currents in the system. These non-linear loads cause poor power factor, low efficiency and interference with communication networks. To improve system performance, Thyristor Controlled Static VAR Compensators (SVCs) are already used in power systems, but they introduce additional harmonics in the AC system. The performance of SVCs are measured by, the Telephone Interference Factor (TIF), the Total Harmonic Current Factor (IT) and the Distortion Factor (D). To optimize the operation of SVCs, the unsymmetrical firing of thyristors is required. Fuzzy Logic Systems (FLSs) can be effectively used to control the firing angle of thyristors by using previous knowledge base and Fuzzy rule base with minimum source reactive power and harmonics injection in the power system. This report presents a Rule Based Fuzzy Logic approach to determine an optimum combination of the phase-wise reactive power generation from SVCs to achieve a balanced reactive power supply from AC system based on TIF.
Tags from this library: No tags from this library for this title. Log in to add tags.
Star ratings
    Average rating: 0.0 (0 votes)
Holdings
Cover image Item type Current library Home library Collection Shelving location Call number Materials specified Vol info URL Copy number Status Notes Date due Barcode Item holds Item hold queue priority Course reserves
22-AIT Thesis (Replacement) Asian Institute of Technology Library AIT Publications AIT Thesis no. ET-00-20 (Browse shelf(Opens below)) 3 Available 30050120748909
40-Archives Asian Institute of Technology Library Archives AIT Thesis no. ET-00-20 (Browse shelf(Opens below)) Available 30050120347397

A thesis submitted in partial fulfilment of the requirements for the degree of Master of Engineering

Thesis (M.Eng.) - Asian Institute of Technology

In modern power systems, there has been a tremendous growth of single-phase non-linear loads supplied from 3-phase distribution systems, which generate unbalanced currents in the system. These non-linear loads cause poor power factor, low efficiency and interference with communication networks. To improve system performance, Thyristor Controlled Static VAR Compensators (SVCs) are already used in power systems, but they introduce additional harmonics in the AC system. The performance of SVCs are measured by, the Telephone Interference Factor (TIF), the Total Harmonic Current Factor (IT) and the Distortion Factor (D). To optimize the operation of SVCs, the unsymmetrical firing of thyristors is required. Fuzzy Logic Systems (FLSs) can be effectively used to control the firing angle of thyristors by using previous knowledge base and Fuzzy rule base with minimum source reactive power and harmonics injection in the power system. This report presents a Rule Based Fuzzy Logic approach to determine an optimum combination of the phase-wise reactive power generation from SVCs to achieve a balanced reactive power supply from AC system based on TIF.